Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,415
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0882 # 04 Y:2014 | 04 | 2014 | INSTALL SET-BACK TIMERS | $142 | $170 | Not Implemented |
OK0882 # 05 Y:2014 | 05 | 2014 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $1,361 | $28 | Not Implemented |
OK0882 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $634 | $2,940 | Not Implemented |
OK0882 # 07 Y:2014 | 07 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,055 | $0 | Not Implemented |
OK0882 # 08 Y:2014 | 08 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,060 | $1,025 | Implemented |
OK0882 # 09 Y:2014 | 09 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,908 | $1,113 | Not Implemented |
OK0882 # 10 Y:2014 | 10 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $333 | $0 | Implemented |
OK0882 # 11 Y:2014 | 11 | 2014 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $5,834 | $6,336 | Not Implemented |
MZ0147 # 01 Y:2014 | 01 | 2014 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $871 | $360 | Implemented |
MZ0147 # 02 Y:2014 | 02 | 2014 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $63 | $235 | Implemented |
MZ0147 # 03 Y:2014 | 03 | 2014 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $63 | $235 | Implemented |
MZ0147 # 04 Y:2014 | 04 | 2014 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $423 | $470 | Implemented |
MZ0147 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,562 | $42,645 | Implemented |
MZ0147 # 06 Y:2014 | 06 | 2014 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $1,184 | $600 | Implemented |
MZ0147 # 07 Y:2014 | 07 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,950 | $5,290 | Not Implemented |
MZ0147 # 08 Y:2014 | 08 | 2014 | INSULATE BARE EQUIPMENT | $2,616 | $2,613 | Not Implemented |
MZ0147 # 09 Y:2014 | 09 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,212 | $420 | Implemented |
MZ0147 # 10 Y:2014 | 10 | 2014 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $3,158 | $250 | Implemented |
WV0491 # 08 Y:2014 | 08 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $541 | $235 | Implemented |
WV0491 # 11 Y:2014 | 11 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $372 | $500 | Not Implemented |
WV0491 # 10 Y:2014 | 10 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $445 | $25 | Implemented |
WV0491 # 09 Y:2014 | 09 | 2014 | USE RADIANT HEATER FOR SPOT HEATING | $485 | $1,450 | Not Implemented |
WV0491 # 01 Y:2014 | 01 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,493 | $14,500 | Not Implemented |
WV0491 # 02 Y:2014 | 02 | 2014 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $6,341 | $1,000 | Implemented |
WV0491 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,694 | $263 | Implemented |