IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

8,415

matching recommendations
Reset
NAICS 326 Plastics and Rubber Products Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LE0372 # 07 Y:2014 07 2014 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $7,519 $6,700 Not Implemented
LE0372 # 08 Y:2014 08 2014 INSTALL TIMERS AND/OR THERMOSTATS $645 $711 Implemented
LE0372 # 09 Y:2014 09 2014 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $24,930 $41,000 Not Implemented
LE0372 # 10 Y:2014 10 2014 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $7,402 $13,500 Not Implemented
LE0372 # 11 Y:2014 11 2014 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $9,045 $16,500 Implemented
LE0372 # 12 Y:2014 12 2014 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $96 $210 Not Implemented
LE0372 # 13 Y:2014 13 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,361 $7,792 Not Implemented
LE0372 # 14 Y:2014 14 2014 INSTALL / REPAIR INSULATION ON STEAM LINES $2,482 $4,118 Not Implemented
LE0372 # 15 Y:2014 15 2014 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $13,408 $64,631 Not Implemented
WM0039 # 01 Y:2014 01 2014 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,902 $6,088 Not Implemented
WM0039 # 02 Y:2014 02 2014 UPGRADE CONTROLS ON COMPRESSORS $12,671 $14,500 Implemented
WM0039 # 03 Y:2014 03 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $936 $2,015 Not Implemented
WM0039 # 04 Y:2014 04 2014 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $3,304 $5,162 Not Implemented
WM0039 # 05 Y:2014 05 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $704 $3,010 Not Implemented
WM0039 # 06 Y:2014 06 2014 INSTALL OCCUPANCY SENSORS $330 $208 Not Implemented
WM0039 # 07 Y:2014 07 2014 TURN OFF EQUIPMENT WHEN NOT IN USE $3,724 $4,550 Not Implemented
WM0039 # 08 Y:2014 08 2014 USE SYNTHETIC LUBRICANT $26,656 $5,209 Implemented
SD0478 # 01 Y:2014 01 2014 REDUCE SCRAP PRODUCTION $30,811 $12,465 Implemented
SD0478 # 02 Y:2014 02 2014 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $13,342 $32,990 Not Implemented
SD0478 # 03 Y:2014 03 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,128 $500 Implemented
SD0478 # 04 Y:2014 04 2014 INSTALL OCCUPANCY SENSORS $2,630 $2,535 Implemented
SD0478 # 05 Y:2014 05 2014 USE PHOTOCELL CONTROLS $2,220 $4,625 Implemented
SU0358 # 01 Y:2014 01 2014 ELIMINATE/REDUCE AN OPERATION $347 $0 Implemented
SU0358 # 02 Y:2014 02 2014 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $13,384 $3,267 Not Implemented
SU0358 # 03 Y:2014 03 2014 INSTALL OCCUPANCY SENSORS $797 $590 Implemented