Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

8,415

matching recommendations
Reset
NAICS 326 Plastics and Rubber Products Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MI0242 # 09 Y:2013 09 2013 INSTALL OCCUPANCY SENSORS $1,486 $137 Not Implemented
MI0242 # 10 Y:2013 10 2013 INSTALL OCCUPANCY SENSORS $1,303 $80 Not Implemented
SU0343 # 01 Y:2013 01 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $24,599 $3,200 Implemented
SU0343 # 02 Y:2013 02 2013 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $6,686 $1,270 Not Implemented
SU0343 # 03 Y:2013 03 2013 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $461 $83 Not Implemented
SU0343 # 04 Y:2013 04 2013 INSTALL OCCUPANCY SENSORS $1,051 $326 Not Implemented
SU0343 # 05 Y:2013 05 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $6,297 $21,467 Not Implemented
AM0639 # 01 Y:2013 01 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,680 $500 Implemented
AM0639 # 02 Y:2013 02 2013 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $7,550 $18 Implemented
AM0639 # 03 Y:2013 03 2013 PAY UTILITY BILLS ON TIME $7,089 $0 Implemented
AM0639 # 04 Y:2013 04 2013 CLEAN CONDENSER TUBES $6,020 $7,540 Implemented
AM0639 # 05 Y:2013 05 2013 OPTIMIZE PLANT POWER FACTOR $5,960 $13,780 Not Implemented
AM0639 # 06 Y:2013 06 2013 USE SYNTHETIC LUBRICANT $4,190 $0 Implemented
AM0639 # 07 Y:2013 07 2013 INSTALL OCCUPANCY SENSORS $1,440 $1,840 Not Implemented
SD0470 # 01 Y:2013 01 2013 REDUCE SCRAP PRODUCTION $34,364 $57,749 Implemented
SD0470 # 02 Y:2013 02 2013 TURN OFF EQUIPMENT WHEN NOT IN USE $10,475 $32,420 Not Implemented
SD0470 # 03 Y:2013 03 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,854 $2,300 Implemented
SD0470 # 04 Y:2013 04 2013 USE PHOTOCELL CONTROLS $4,614 $4,625 Implemented
SD0470 # 05 Y:2013 05 2013 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $4,160 $14,000 Not Implemented
SD0470 # 06 Y:2013 06 2013 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,569 $600 Not Implemented
SD0470 # 07 Y:2013 07 2013 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD $3,245 $9,125 Not Implemented
SD0470 # 08 Y:2013 08 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,241 $2,390 Not Implemented
UA0101 # 01 Y:2013 01 2013 INSTALL TIMERS AND/OR THERMOSTATS $16,195 $150 Implemented
UA0101 # 02 Y:2013 02 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $14,664 $7,400 Not Implemented
UA0101 # 03 Y:2013 03 2013 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $5,670 $80 Implemented