Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
31
matching recommendationsNAICS | 33131 | Alumina and Aluminum Production and Processing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0692 # 09 Y:2015 | 09 | 2015 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $480 | $10 | Implemented |
AM0692 # 08 Y:2015 | 08 | 2015 | DISCONNECT BALLASTS | $533 | $1,100 | Implemented |
AM0692 # 07 Y:2015 | 07 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $870 | $6 | Implemented |
AM0692 # 01 Y:2015 | 01 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $12,970 | $10,000 | Implemented |
AM0692 # 02 Y:2015 | 02 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,830 | $5,000 | Implemented |
AM0692 # 03 Y:2015 | 03 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,880 | $16,750 | Implemented |
AM0692 # 04 Y:2015 | 04 | 2015 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,124 | $0 | Implemented |
AM0692 # 05 Y:2015 | 05 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,115 | $0 | Implemented |
AM0692 # 06 Y:2015 | 06 | 2015 | USE SYNTHETIC LUBRICANT | $1,560 | $0 | Implemented |
UK1508 # 08 Y:2015 | 08 | 2015 | UPGRADE OBSOLETE EQUIPMENT | $1,302 | $746 | Implemented |
UK1508 # 07 Y:2015 | 07 | 2015 | INSTALL OCCUPANCY SENSORS | $1,722 | $193 | Implemented |
UK1508 # 10 Y:2015 | 10 | 2015 | INSTALL COMMON HEADER ON COMPRESSORS | $4,650 | $2,950 | Implemented |
UK1508 # 11 Y:2015 | 11 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,700 | $1,700 | Implemented |
UK1508 # 12 Y:2015 | 12 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,063 | $3,260 | Implemented |
UK1508 # 13 Y:2015 | 13 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $21,138 | $12,000 | Implemented |
MZ0187 # 02 Y:2015 | 02 | 2015 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $9,635 | $6,500 | Implemented |
MZ0187 # 03 Y:2015 | 03 | 2015 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $684 | $380 | Implemented |
MZ0187 # 04 Y:2015 | 04 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,096 | $5,600 | Implemented |
MZ0187 # 05 Y:2015 | 05 | 2015 | REPAIR AND ELIMINATE STEAM LEAKS | $3,321 | $1,440 | Implemented |
WV0506 # 05 Y:2015 | 05 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,457 | $7,450 | Implemented |
WV0506 # 10 Y:2015 | 10 | 2015 | DEVELOP A REPAIR/REPLACE POLICY | $790 | $1,205 | Implemented |
WV0506 # 09 Y:2015 | 09 | 2015 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $1,221 | $1,000 | Implemented |
WV0506 # 07 Y:2015 | 07 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,579 | $270 | Implemented |
WV0506 # 02 Y:2015 | 02 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,853 | $7,076 | Implemented |
WV0504 # 10 Y:2015 | 10 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $293 | $69 | Implemented |