Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,785

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0426 # 07 Y:1991 07 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $345 $556 Implemented
TN0426 # 08 Y:1991 08 1991 OPTIMIZE PLANT POWER FACTOR $803 $1,375 Implemented
TN0431 # 01 Y:1991 01 1991 HEAT WATER WITH EXHAUST HEAT $15,356 $31,200 Not Implemented
TN0431 # 02 Y:1991 02 1991 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,377 $0 Not Implemented
TN0431 # 03 Y:1991 03 1991 INSTALL TIMERS AND/OR THERMOSTATS $2,926 $1,200 Not Implemented
TN0431 # 04 Y:1991 04 1991 IMPROVE LUBRICATION PRACTICES $854 $420 Not Implemented
TN0431 # 05 Y:1991 05 1991 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $290 $25 Not Implemented
TN0431 # 06 Y:1991 06 1991 INSTALL SOLID WASTE INCINERATOR FOR HEAT $272 $142 Not Implemented
TN0431 # 07 Y:1991 07 1991 INSULATE BARE EQUIPMENT $210 $335 Not Implemented
AM0119 # 01 Y:1991 01 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $510 $148 Implemented
AM0119 # 02 Y:1991 02 1991 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $420 $0 Implemented
AM0119 # 03 Y:1991 03 1991 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $250 $260 Implemented
AM0119 # 04 Y:1991 04 1991 INSTALL TIMERS AND/OR THERMOSTATS $103 $320 Implemented
AM0121 # 01 Y:1991 01 1991 OPTIMIZE PLANT POWER FACTOR $21,900 $17,552 Not Implemented
AM0121 # 02 Y:1991 02 1991 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,345 $600 Not Implemented
AM0121 # 03 Y:1991 03 1991 INSTALL TIMERS AND/OR THERMOSTATS $1,150 $800 Not Implemented
AM0121 # 04 Y:1991 04 1991 IMPROVE LUBRICATION PRACTICES $520 $0 Not Implemented
AM0121 # 05 Y:1991 05 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $180 $0 Not Implemented
AM0121 # 06 Y:1991 06 1991 ELIMINATE LEAKS IN WATER LINES AND VALVES $515 $0 Not Implemented
AS0023 # 01 Y:1991 01 1991 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,685 $1,000 Not Implemented
AS0023 # 02 Y:1991 02 1991 USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST $230,323 $780,000 Not Implemented
AS0023 # 03 Y:1991 03 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,633 $440 Not Implemented
AS0023 # 04 Y:1991 04 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,629 $2,688 Not Implemented
AS0023 # 05 Y:1991 05 1991 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $10,762 $0 Not Implemented
AS0023 # 06 Y:1991 06 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,767 $14,294 Not Implemented