Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
88
matching recommendationsSIC | 3471 | Plating And Polishing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0248 # 07 Y:1995 | 07 | 1995 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $310 | $500 | Implemented |
AM0248 # 06 Y:1995 | 06 | 1995 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $350 | $0 | Implemented |
AM0248 # 05 Y:1995 | 05 | 1995 | UPGRADE OBSOLETE EQUIPMENT | $790 | $655 | Implemented |
AM0248 # 04 Y:1995 | 04 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $750 | $200 | Implemented |
AM0248 # 03 Y:1995 | 03 | 1995 | INSULATE BARE EQUIPMENT | $1,020 | $290 | Implemented |
AM0248 # 02 Y:1995 | 02 | 1995 | OPTIMIZE PLANT POWER FACTOR | $8,584 | $8,750 | Not Implemented |
SF0061 # 06 Y:1995 | 06 | 1995 | COVER OPEN TANKS | $3,373 | $1,560 | Not Implemented |
SF0061 # 10 Y:1995 | 10 | 1995 | TREAT AND REUSE RINSE WATERS | $10,340 | $6,344 | Not Implemented |
SF0061 # 09 Y:1995 | 09 | 1995 | REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS | $7,532 | $1,288 | Implemented |
SF0061 # 08 Y:1995 | 08 | 1995 | USE PRECIPITATING AGENTS IN WASTE WATER TREATMENT THAT PRODUCE THE LEAST QUANTITY OF WASTE | $2,880 | $25,300 | Not Implemented |
SF0061 # 07 Y:1995 | 07 | 1995 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $6,048 | $2,955 | Not Implemented |
SF0061 # 05 Y:1995 | 05 | 1995 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $733 | $1,300 | Not Implemented |
SF0061 # 04 Y:1995 | 04 | 1995 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,658 | $2,208 | Implemented |
SF0061 # 03 Y:1995 | 03 | 1995 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $347 | $1,570 | Not Implemented |
SF0061 # 01 Y:1995 | 01 | 1995 | INSTALL OCCUPANCY SENSORS | $1,935 | $360 | Not Implemented |
SF0061 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $129 | $170 | Implemented |
MA0339 # 06 Y:1995 | 06 | 1995 | RECOVERY METALS FROM RINSE WATER(EVAP., ION EXCHANGE, RO, ELECTROLYSIS, ELECTRODIALYSIS) AND REUSE RINSE WATER | $23,990 | $500 | Not Implemented |
MA0339 # 05 Y:1995 | 05 | 1995 | RECOVERY METALS FROM RINSE WATER(EVAP., ION EXCHANGE, RO, ELECTROLYSIS, ELECTRODIALYSIS) AND REUSE RINSE WATER | $57,939 | $118,450 | Not Implemented |
MA0339 # 04 Y:1995 | 04 | 1995 | INSULATE BARE EQUIPMENT | $504 | $1,010 | Not Implemented |
MA0339 # 03 Y:1995 | 03 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $653 | $0 | Implemented |
MA0339 # 02 Y:1995 | 02 | 1995 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $1,027 | $3,770 | Implemented |
MA0339 # 01 Y:1995 | 01 | 1995 | BURN A LESS EXPENSIVE GRADE OF FUEL | $4,128 | $1,860 | Implemented |
MA0339 # 07 Y:1995 | 07 | 1995 | REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS | $824 | $3,000 | Not Implemented |
AS0143 # 06 Y:1995 | 06 | 1995 | INSTALL / REPAIR INSULATION ON STEAM LINES | $349 | $599 | Implemented |
AS0143 # 05 Y:1995 | 05 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,823 | $500 | Implemented |