Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
407
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0217 # 01 Y:1984 | 01 | 1984 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $51,259 | $42,740 | Not Implemented |
TN0217 # 02 Y:1984 | 02 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $24,926 | $1,300 | Implemented |
TN0217 # 03 Y:1984 | 03 | 1984 | REPAIR AND ELIMINATE STEAM LEAKS | $22,604 | $1,425 | Implemented |
TN0218 # 01 Y:1984 | 01 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $8,908 | $15,000 | Not Implemented |
CO0001 # 02 Y:1984 | 02 | 1984 | USE MINIMUM STEAM OPERATING PRESSURE | $231 | $0 | Implemented |
CO0001 # 03 Y:1984 | 03 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,145 | $2,500 | Implemented |
CO0001 # 05 Y:1984 | 05 | 1984 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $202 | $210 | Implemented |
CO0001 # 06 Y:1984 | 06 | 1984 | INSULATE BARE EQUIPMENT | $276 | $210 | Implemented |
GT0218 # 03 Y:1984 | 03 | 1984 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $1,575 | $520 | Implemented |
GT0225 # 03 Y:1984 | 03 | 1984 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $1,720 | $4,000 | Not Implemented |
KU0128 # 03 Y:1984 | 03 | 1984 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $2,531 | $178 | Not Implemented |
KU0128 # 06 Y:1984 | 06 | 1984 | RECOVER WASTE HEAT FROM EQUIPMENT | $876 | $1,200 | Not Implemented |
LT0001 # 05 Y:1984 | 05 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $66,754 | $0 | Implemented |
OK0144 # 02 Y:1984 | 02 | 1984 | INSULATE BARE EQUIPMENT | $1,714 | $580 | Not Implemented |
TN0214 # 01 Y:1984 | 01 | 1984 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $11,671 | $29,800 | Not Implemented |
TN0214 # 04 Y:1984 | 04 | 1984 | INSULATE BARE EQUIPMENT | $480 | $627 | Not Implemented |
TN0215 # 01 Y:1984 | 01 | 1984 | COVER OPEN TANKS | $10,482 | $3,500 | Implemented |
TN0215 # 03 Y:1984 | 03 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,092 | $300 | Implemented |
TN0215 # 07 Y:1984 | 07 | 1984 | USE MINIMUM STEAM OPERATING PRESSURE | $427 | $0 | Implemented |
TN0216 # 01 Y:1984 | 01 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,564 | $4,000 | Not Implemented |
TN0216 # 03 Y:1984 | 03 | 1984 | COVER OPEN TANKS | $1,096 | $75 | Not Implemented |
TN0216 # 04 Y:1984 | 04 | 1984 | COVER OPEN TANKS | $273 | $75 | Not Implemented |
TN0216 # 06 Y:1984 | 06 | 1984 | INSULATE BARE EQUIPMENT | $422 | $53 | Not Implemented |
TS0001 # 03 Y:1984 | 03 | 1984 | USE MINIMUM SAFE OVEN VENTILATION | $335 | $300 | Implemented |
UD0131 # 05 Y:1984 | 05 | 1984 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $2,576 | $4,000 | Implemented |