Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

216

matching recommendations
Reset
ARC 2.72 SPACE CONDITIONING
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0423 # 03 Y:1998 03 1998 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,343 $234 Implemented
MA0423 # 01 Y:1998 01 1998 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $3,806 $300 Implemented
MA0422 # 04 Y:1998 04 1998 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $452 $1,270 Implemented
GT0656 # 02 Y:1998 02 1998 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $5,934 $4,000 Not Implemented
OK0562 # 04 Y:1998 04 1998 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $526 $242 Not Implemented
MS0125 # 03 Y:1998 03 1998 INSTALL TIMERS AND/OR THERMOSTATS $125 $236 Implemented
ND0310 # 03 Y:1998 03 1998 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $56,650 $65,000 Implemented
ND0310 # 02 Y:1998 02 1998 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $27,164 $9,600 Implemented
ND0310 # 04 Y:1998 04 1998 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS $1,487 $0 Implemented
OD0125 # 03 Y:1998 03 1998 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $6,650 $630 Implemented
OD0125 # 02 Y:1998 02 1998 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $704 $840 Implemented
GT0647 # 04 Y:1998 04 1998 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $430 $1,992 Not Implemented
GT0647 # 03 Y:1998 03 1998 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $860 $4,625 Not Implemented
MS0123 # 07 Y:1998 07 1998 INSTALL TIMERS AND/OR THERMOSTATS $4,448 $1,888 Implemented
MS0123 # 02 Y:1998 02 1998 USE RADIANT HEATER FOR SPOT HEATING $7,783 $9,763 Implemented
WV0155 # 02 Y:1998 02 1998 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $3,108 $4,432 Not Implemented
MS0119 # 01 Y:1998 01 1998 USE WATER ON AIR CONDITIONING EXCHANGER TO IMPROVE HEAT TRANSFER AND INCREASE AIR CONDITIONER EFFICIENCY $24,225 $7,315 Not Implemented
MS0124 # 02 Y:1998 02 1998 INSTALL TIMERS AND/OR THERMOSTATS $2,507 $944 Implemented
UL0209 # 01 Y:1998 01 1998 INSTALL TIMERS AND/OR THERMOSTATS $2,561 $2,000 Not Implemented
MS0122 # 05 Y:1998 05 1998 INSTALL TIMERS AND/OR THERMOSTATS $896 $472 Not Implemented
AS0239 # 02 Y:1998 02 1998 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $2,088 $3,600 Not Implemented
HO0188 # 02 Y:1998 02 1998 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $6,007 $4,000 Not Implemented
BD0122 # 02 Y:1998 02 1998 USE RADIANT HEATER FOR SPOT HEATING $3,315 $7,200 Not Implemented
AS0238 # 01 Y:1998 01 1998 INSTALL TIMERS AND/OR THERMOSTATS $901 $1,875 Not Implemented
OD0122 # 06 Y:1998 06 1998 INSTALL TIMERS AND/OR THERMOSTATS $2,871 $1,050 Implemented