IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,600

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0229 # 02 Y:1991 02 1991 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,963 $0 Not Implemented
MA0229 # 03 Y:1991 03 1991 OPTIMIZE PLANT POWER FACTOR $1,759 $4,685 Not Implemented
MA0229 # 04 Y:1991 04 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,388 $4,900 Implemented
MA0229 # 05 Y:1991 05 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $825 $1,900 Not Implemented
MA0229 # 06 Y:1991 06 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $520 $1,749 Implemented
MA0229 # 07 Y:1991 07 1991 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $430 $170 Implemented
MA0230 # 01 Y:1991 01 1991 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $7,447 $11,800 Not Implemented
MA0230 # 02 Y:1991 02 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,665 $30,800 Not Implemented
MA0230 # 03 Y:1991 03 1991 INSTALL SET-BACK TIMERS $1,842 $300 Not Implemented
MA0230 # 04 Y:1991 04 1991 INSULATE BARE EQUIPMENT $4,761 $4,725 Not Implemented
MA0230 # 05 Y:1991 05 1991 OPTIMIZE PLANT POWER FACTOR $3,643 $9,600 Not Implemented
MA0230 # 06 Y:1991 06 1991 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,264 $0 Not Implemented
MA0230 # 07 Y:1991 07 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,201 $430 Implemented
MA0145 # 01 Y:1989 01 1989 TURN OFF EQUIPMENT WHEN NOT IN USE $3,559 $0 Not Implemented
MA0145 # 02 Y:1989 02 1989 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $3,230 $4,500 Implemented
MA0145 # 03 Y:1989 03 1989 RECOVER WASTE HEAT FROM EQUIPMENT $2,036 $4,870 Not Implemented
MA0145 # 04 Y:1989 04 1989 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,228 $160 Not Implemented
MA0145 # 05 Y:1989 05 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $824 $356 Not Implemented
MA0145 # 06 Y:1989 06 1989 TURN OFF EQUIPMENT WHEN NOT IN USE $246 $87 Implemented
MA0145 # 07 Y:1989 07 1989 INSTALL SET-BACK TIMERS $206 $525 Implemented
MA0145 # 08 Y:1989 08 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $125 $0 Implemented
MA0013 # 01 Y:1985 01 1985 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $949 $171 Implemented
MA0013 # 02 Y:1985 02 1985 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $7,976 $8,800 Implemented
MA0013 # 03 Y:1985 03 1985 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $3,897 $1,850 Not Implemented
MA0013 # 04 Y:1985 04 1985 DISCONNECT BALLASTS $1,543 $900 Implemented