IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

418

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NV0109 # 06 Y:1998 06 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $776 $157 Implemented
NV0109 # 07 Y:1998 07 1998 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $353 $0 Implemented
NV0109 # 10 Y:1998 10 1998 ELIMINATE LEAKS IN WATER LINES AND VALVES $120 $150 Implemented
NV0109 # 13 Y:1998 13 1998 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $1,493 $0 Implemented
NV0106 # 09 Y:1998 09 1998 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $986 $0 Implemented
NV0106 # 05 Y:1998 05 1998 ELIMINATE/REDUCE AN OPERATION $9,796 $0 Implemented
NV0106 # 08 Y:1998 08 1998 USE IN-PROCESS RECYCLING WHENEVER POSSIBLE $327 $50 Implemented
NV0105 # 02 Y:1998 02 1998 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $9,271 $21,600 Implemented
NV0105 # 03 Y:1998 03 1998 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $2,061 $0 Implemented
NV0105 # 04 Y:1998 04 1998 SIZE AIR HANDLING GRILLS/ DUCT/S COILS TO MINIMIZE AIR RESISTANCE $1,030 $1,267 Implemented
NV0105 # 05 Y:1998 05 1998 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $9,488 $1,080 Implemented
NV0105 # 09 Y:1998 09 1998 USE RADIANT HEATER FOR SPOT HEATING $2,679 $8,064 Implemented
NV0105 # 10 Y:1998 10 1998 $52,000 $14,200 Implemented
NV0105 # 12 Y:1998 12 1998 REDUCE SCRAP PRODUCTION $64,064 $375,750 Implemented
NV0104 # 01 Y:1998 01 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $867 $2,852 Implemented
NV0104 # 03 Y:1998 03 1998 REPLACE BOILER $12,990 $48,188 Implemented
NV0103 # 01 Y:1998 01 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $179 $137 Implemented
NV0103 # 02 Y:1998 02 1998 USE PHOTOCELL CONTROLS $550 $200 Implemented
NV0103 # 03 Y:1998 03 1998 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $912 $750 Implemented
NV0103 # 04 Y:1998 04 1998 $44,986 $9,960 Implemented
NV0103 # 05 Y:1998 05 1998 $22,940 $7,800 Implemented
NV0102 # 02 Y:1998 02 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $995 $950 Implemented
NV0102 # 06 Y:1998 06 1998 $28,225 $116,750 Implemented
NV0126 # 01 Y:1999 01 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $284 $70 Implemented
NV0126 # 04 Y:1999 04 1999 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $821 $1,300 Implemented