Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 1996 |
Principal Product | Bottled soft drinks |
NAICS | n/a |
SIC | 2086 - Bottled And Canned Soft Drinks |
Sales | $50,000,000-$100,000,000 |
# of Employees | 95 |
Plant Area (Sq.Ft.) | 335,461 |
Annual Production | 50,300 Thousand Gallons |
Production Hrs. Annual | 5,565 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $344,963 | 8,054,514 | kWh | $0.04 |
Electricity Demand | $154,916 | 22,715 | kW-months/year | $6.82 |
Electricity Fees | $8,031 | - | $ | - |
TOTAL ENERGY COSTS | $511,110 | |||
RECOMMENDED SAVINGS* | $27,480 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $8,700 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (haz) | Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | gal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $13,100 Cost: $28,200 |
- | - | - | - | $13,100 | - | - | - |
- - kWh |
- - kW-months/year |
$13,100 - $ |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $8,700 Cost: - |
$8,700 | 309,789 | - | - | - | - | - | - |
$8,700 309,789 kWh |
- - kW-months/year |
- - $ |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $2,980 Cost: - |
$1,460 | 52,169 | $1,520 | 141 | - | - | - | - |
$1,460 52,169 kWh |
$1,520 141 kW-months/year |
- - $ |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.8211 CONVERT TO AQUEOUS CLEANING SYSTEM |
Savings: $2,700 Cost: $1,028 |
- | - | - | - | - | - | $2,700 | 3,100 |
- - kWh |
- - kW-months/year |
- - $ |
$2,700 3,100 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $27,480 Cost: $29,228 |
$10,160 | 361,958 | $1,520 | 141 | $13,100 | - | $2,700 | 3,100 | $10,160 361,958 kWh |
$1,520 141 kW-months/year |
$13,100 - $ |
$2,700 3,100 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $8,700 Cost: - |
$8,700 | 309,789 | - | - | - | - | - | - | $8,700 309,789 kWh |
- - kW-months/year |
- - $ |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | gal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (haz) | Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (haz) |