Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 1996 |
Principal Product | Commercial & Industrial Indoor and outdoor lighting fixtures |
NAICS | n/a |
SIC | 3648 - Lighting Equipment, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 250,000 |
Annual Production | 1,519,200 Pieces |
Production Hrs. Annual | 4,545 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $97,449 | 1,879,836 | kWh | $0.05 |
Electricity Demand | $18,132 | 5,453 | kW-months/year | $3.33 |
Electricity Fees | $1,443 | - | $ | - |
Natural Gas | $72,863 | 14,168 | MMBtu | $5.14 |
TOTAL ENERGY COSTS | $206,367 | |||
RECOMMENDED SAVINGS* | $99,532 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $64,865 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (haz) | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (haz) | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | gal | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $6,248 Cost: $11,200 |
- | - | $6,248 | 462 | - | - | - | - | - | - |
- - kWh |
$6,248 462 kW-months/year |
- - $ |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $2,147 Cost: - |
- | - | - | - | $2,147 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,147 - $ |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,170 Cost: $210 |
$2,170 | 94,373 | - | - | - | - | - | - | - | - |
$2,170 94,373 kWh |
- - kW-months/year |
- - $ |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $1,860 Cost: - |
$1,860 | 81,184 | - | - | - | - | - | - | - | - |
$1,860 81,184 kWh |
- - kW-months/year |
- - $ |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.8123 PAY UTILITY BILLS ON TIME |
Savings: $267 Cost: - |
- | - | - | - | $267 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$267 - $ |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $34,400 Cost: - |
- | - | - | - | - | - | - | - | $34,400 | 502,000 |
- - kWh |
- - kW-months/year |
- - $ |
- - gal |
$34,400 502,000 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.2121 CONVERT TO ELECTROSTATIC POWDER COATING |
Savings: $52,440 Cost: $160,000 |
- | - | - | - | - | - | $52,440 | 31,189 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$52,440 31,189 gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $99,532 Cost: $171,410 |
$4,030 | 175,557 | $6,248 | 462 | $2,414 | - | $52,440 | 31,189 | $34,400 | 502,000 | $4,030 175,557 kWh |
$6,248 462 kW-months/year |
$2,414 - $ |
$52,440 31,189 gal |
$34,400 502,000 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $64,865 Cost: $171,410 |
$4,030 | 175,557 | $6,248 | 462 | $2,147 | - | $52,440 | 31,189 | - | - | $4,030 175,557 kWh |
$6,248 462 kW-months/year |
$2,147 - $ |
$52,440 31,189 gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | gal | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (haz) | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (haz) | Solid Waste (non-haz) |