Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Texas A&M, College Station
Assessment Year 1996
Principal Product Fiberglass roofing shingle mats
NAICS n/a
SIC 3089 - Plastics Products, Nec
Sales $10,000,000-$50,000,000
# of Employees 56
Plant Area (Sq.Ft.) 24,000
Annual Production 3,100,000 Thousand Feet
Production Hrs. Annual 8,592
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $422,961 12,501,759 kWh $0.03
Electricity Demand $198,377 26,218 kW-months/year $7.57
Electricity Fees $180 - $ -
Natural Gas $421,239 213,811 MMBtu $1.97
TOTAL ENERGY COSTS $1,191,527
RECOMMENDED SAVINGS* $325,930 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $211,110
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Solid Waste (non-haz) Electricity Usage Electricity Demand Natural Gas Solid Waste (non-haz)
$ kWh $ kW-months/year $ MMBtu $ lb
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$167,000
Cost:
$73,600
- - - - $167,000 85,000 - - -
-
kWh
-
-
kW-months/year
$167,000
85,000
MMBtu
-
-
lb
02: 2.1135 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY Savings:
$7,330
Cost:
$400
- - - - $7,330 3,720 - - -
-
kWh
-
-
kW-months/year
$7,330
3,720
MMBtu
-
-
lb
03: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED Savings:
$2,830
Cost:
-
$1,620 81,184 $1,210 113 - - - - $1,620
81,184
kWh
$1,210
113
kW-months/year
-
-
MMBtu
-
-
lb
04: 3.1162 USE LESS WASTEFUL PACKAGING Savings:
$97,900
Cost:
-
- - - - - - $97,900 88,110 -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$97,900
88,110
lb
05: 3.1182 MAKE A NEW BY-PRODUCT Savings:
$36,780
Cost:
-
- - - - - - $36,780 6,400 -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$36,780
6,400
lb
06: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE Savings:
$14,090
Cost:
-
- - - - - - $14,090 41,700 -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$14,090
41,700
lb
TOTAL RECOMMENDED Savings:
$325,930
Cost:
$74,000
$1,620 81,184 $1,210 113 $174,330 88,720 $148,770 136,210 $1,620
81,184
kWh
$1,210
113
kW-months/year
$174,330
88,720
MMBtu
$148,770
136,210
lb
TOTAL IMPLEMENTED Savings:
$211,110
Cost:
$74,000
- - - - $174,330 88,720 $36,780 6,400 -
-
kWh
-
-
kW-months/year
$174,330
88,720
MMBtu
$36,780
6,400
lb
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ lb
Electricity Usage Electricity Demand Natural Gas Solid Waste (non-haz) Electricity Usage Electricity Demand Natural Gas Solid Waste (non-haz)