Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 2001 |
Principal Product | Oriented strand board |
NAICS | n/a |
SIC | 2493 - Reconstituted Wood Products |
Sales | $50,000,000-$100,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 213,000 |
Annual Production | 310,000 Thousand Feet |
Production Hrs. Annual | 8,448 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $2,687,352 | 73,062,000 | kWh | $0.04 |
Electricity Demand | $852,823 | 128,190 | kW-months/year | $6.65 |
Natural Gas | $2,233,929 | 600,637 | MMBtu | $3.72 |
TOTAL ENERGY COSTS | $5,774,104 | |||
RECOMMENDED SAVINGS* | $162,350 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $68,600 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $67,500 Cost: $1,500 |
- | - | - | - | $67,500 | 13,335 | - | - | - | - |
- - kWh |
- - kW-months/year |
$67,500 13,335 MMBtu |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $24,500 Cost: - |
- | - | - | - | - | - | - | - | $24,500 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$24,500 - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $20,000 Cost: $60,000 |
- | - | $20,000 | 2,834 | - | - | - | - | - | - |
- - kWh |
$20,000 2,834 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $18,400 Cost: - |
- | - | - | - | - | - | - | - | $18,400 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$18,400 - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $13,950 Cost: - |
$11,250 | 268,000 | $2,700 | 381 | - | - | - | - | - | - |
$11,250 268,000 kWh |
$2,700 381 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1121 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING |
Savings: $11,700 Cost: $1,400 |
- | - | - | - | - | - | - | - | $11,700 | 134,000 |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$11,700 134,000 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $5,700 Cost: - |
$3,800 | 90,000 | $1,900 | 270 | - | - | - | - | - | - |
$3,800 90,000 kWh |
$1,900 270 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.6194 SHIP HYDRAULIC OIL TO SECONDARY FUEL PROGRAM |
Savings: $600 Cost: - |
- | - | - | - | - | - | $600 | 40,000 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$600 40,000 gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $162,350 Cost: $62,900 |
$15,050 | 358,000 | $24,600 | 3,485 | $67,500 | 13,335 | $600 | 40,000 | $54,600 | 134,000 | $15,050 358,000 kWh |
$24,600 3,485 kW-months/year |
$67,500 13,335 MMBtu |
$600 40,000 gal |
$54,600 134,000 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $68,600 Cost: $60,000 |
$3,800 | 90,000 | $21,900 | 3,104 | - | - | - | - | $42,900 | - | $3,800 90,000 kWh |
$21,900 3,104 kW-months/year |
- - MMBtu |
- - gal |
$42,900 - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) |