Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Texas A&M, College Station
Assessment Year 2002
Principal Product compressed air tools
NAICS n/a
SIC 3546 - Power-driven Handtools
Sales $5,000,000-$10,000,000
# of Employees 40
Plant Area (Sq.Ft.) 30,000
Annual Production 41,850 Pieces
Production Hrs. Annual 5,749
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $18,641 690,411 kWh $0.03
Electricity Demand $26,918 3,786 kW-months/year $7.11
LPG $6,415 412 MMBtu $15.57
TOTAL ENERGY COSTS $51,974
RECOMMENDED SAVINGS* $3,310 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $1,700
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Solid Waste (non-haz) Electricity Usage Electricity Demand Solid Waste (non-haz)
$ kWh $ kW-months/year $ lb
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,330
Cost:
$300
$1,330 49,200 - - - - $1,330
49,200
kWh
-
-
kW-months/year
-
-
lb
02: 3.7198 REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT Savings:
$920
Cost:
$699
- - - - $920 6,146 -
-
kWh
-
-
kW-months/year
$920
6,146
lb
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$690
Cost:
$210
$290 10,600 $400 56 - - $290
10,600
kWh
$400
56
kW-months/year
-
-
lb
04: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED Savings:
$190
Cost:
-
$120 4,340 $70 10 - - $120
4,340
kWh
$70
10
kW-months/year
-
-
lb
05: 3.7132 REUSE RAGS UNTIL COMPLETELY SOILED Savings:
$180
Cost:
-
- - - - $180 100 -
-
kWh
-
-
kW-months/year
$180
100
lb
TOTAL RECOMMENDED Savings:
$3,310
Cost:
$1,209
$1,740 64,140 $470 66 $1,100 6,246 $1,740
64,140
kWh
$470
66
kW-months/year
$1,100
6,246
lb
TOTAL IMPLEMENTED Savings:
$1,700
Cost:
$300
$1,450 53,540 $70 10 $180 100 $1,450
53,540
kWh
$70
10
kW-months/year
$180
100
lb
Savings
Cost
$ kWh $ kW-months/year $ lb
Electricity Usage Electricity Demand Solid Waste (non-haz) Electricity Usage Electricity Demand Solid Waste (non-haz)