Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 2002 |
Principal Product | Rebuilt turbine engine components |
NAICS | n/a |
SIC | 3724 - Aircraft Engines And Engine Parts |
Sales | $5,000,000-$10,000,000 |
# of Employees | 34 |
Plant Area (Sq.Ft.) | 38,500 |
Annual Production | 2,700 Pieces |
Production Hrs. Annual | 2,192 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $50,749 | 747,600 | kWh | $0.07 |
Electricity Fees | $3,989 | - | $ | - |
Natural Gas | $8,202 | 892 | MMBtu | $9.20 |
TOTAL ENERGY COSTS | $62,940 | |||
RECOMMENDED SAVINGS* | $31,892 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $18,602 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $18,602 Cost: $2,302 |
- | - | - | - | - | - | $4,602 | - | - | - | $14,000 | - |
- - kWh |
- - kW-months/year |
- - lb |
$4,602 - $ |
- - $ |
$14,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $5,050 Cost: $750 |
- | - | - | - | - | - | - | - | $5,050 | - | - | - |
- - kWh |
- - kW-months/year |
- - lb |
- - $ |
$5,050 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.5217 REUSE / RECYCLE/ SELL PAPER PRODUCTS |
Savings: $2,935 Cost: $6,000 |
- | - | - | - | $2,935 | 8,775 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,935 8,775 lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.445 INSTALL EQUIPMENT TO MOVE PRODUCT |
Savings: $1,880 Cost: $5,830 |
- | - | - | - | - | - | $1,880 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - lb |
$1,880 - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $1,300 Cost: $1,160 |
$1,300 | 31,200 | - | - | - | - | - | - | - | - | - | - |
$1,300 31,200 kWh |
- - kW-months/year |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $765 Cost: - |
$425 | 10,350 | $340 | 56 | - | - | - | - | - | - | - | - |
$425 10,350 kWh |
$340 56 kW-months/year |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $710 Cost: $200 |
$710 | 17,230 | - | - | - | - | - | - | - | - | - | - |
$710 17,230 kWh |
- - kW-months/year |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $650 Cost: - |
- | - | - | - | $650 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$650 - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $31,892 Cost: $16,242 |
$2,435 | 58,780 | $340 | 56 | $3,585 | 8,775 | $6,482 | - | $5,050 | - | $14,000 | - | $2,435 58,780 kWh |
$340 56 kW-months/year |
$3,585 8,775 lb |
$6,482 - $ |
$5,050 - $ |
$14,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $18,602 Cost: $2,302 |
- | - | - | - | - | - | $4,602 | - | - | - | $14,000 | - | - - kWh |
- - kW-months/year |
- - lb |
$4,602 - $ |
- - $ |
$14,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost |