IAC logo
IAC Assessment: AM0455
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: AM0455
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Texas A&M, College Station
Assessment Year 2004
Principal Product Industrial and agricultural mowing equipment
NAICS 333112 - Lawn and Garden Tractor and Home Lawn and Garden Equipment Manufacturing
SIC 3524 - Lawn And Garden Equipment
Sales $50,000,000-$100,000,000
# of Employees 150
Plant Area (Sq.Ft.) 275,000
Annual Production 2,640 Pieces
Production Hrs. Annual 2,228
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $132,340 2,471,665 kWh $0.05
Electricity Fees $6,000 - $ -
Natural Gas $64,338 8,420 MMBtu $7.64
TOTAL ENERGY COSTS $202,678
RECOMMENDED SAVINGS* $147,978 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $1,528
#|Description Savings
Cost
Status Electricity Usage Natural Gas Solid Waste (non-haz) Administrative Changes Ancillary Material Cost Electricity Usage Natural Gas Solid Waste (non-haz) Administrative Changes Ancillary Material Cost
$ kWh $ MMBtu $ lb $ $ $ $
01: 3.2123 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS Savings:
$141,300
Cost:
$680
- - - - $44,200 31,600 - - $97,100 - -
-
kWh
-
-
MMBtu
$44,200
31,600
lb
-
-
$
$97,100
-
$
02: 3.7132 REUSE RAGS UNTIL COMPLETELY SOILED Savings:
$1,800
Cost:
-
- - - - - - - - $1,800 - -
-
kWh
-
-
MMBtu
-
-
lb
-
-
$
$1,800
-
$
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$3,350
Cost:
$14,400
- - $3,350 439 - - - - - - -
-
kWh
$3,350
439
MMBtu
-
-
lb
-
-
$
-
-
$
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$680
Cost:
$1,500
$680 12,500 - - - - - - - - $680
12,500
kWh
-
-
MMBtu
-
-
lb
-
-
$
-
-
$
05: 2.8112 COMBINE UTILITY METERS Savings:
$528
Cost:
-
- - - - - - $528 - - - -
-
kWh
-
-
MMBtu
-
-
lb
$528
-
$
-
-
$
06: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$200
Cost:
-
$200 3,700 - - - - - - - - $200
3,700
kWh
-
-
MMBtu
-
-
lb
-
-
$
-
-
$
07: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED Savings:
$120
Cost:
$74
$120 2,270 - - - - - - - - $120
2,270
kWh
-
-
MMBtu
-
-
lb
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$147,978
Cost:
$16,654
$1,000 18,470 $3,350 439 $44,200 31,600 $528 - $98,900 - $1,000
18,470
kWh
$3,350
439
MMBtu
$44,200
31,600
lb
$528
-
$
$98,900
-
$
TOTAL IMPLEMENTED Savings:
$1,528
Cost:
$1,574
$1,000 18,470 - - - - $528 - - - $1,000
18,470
kWh
-
-
MMBtu
-
-
lb
$528
-
$
-
-
$
Savings
Cost
$ kWh $ MMBtu $ lb $ $ $ $
Electricity Usage Natural Gas Solid Waste (non-haz) Administrative Changes Ancillary Material Cost Electricity Usage Natural Gas Solid Waste (non-haz) Administrative Changes Ancillary Material Cost