Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Texas A&M, College Station
Assessment Year 2004
Principal Product Aluminum windows
NAICS 332321 - Metal Window and Door Manufacturing
SIC 3442 - Metal Doors, Sash, And Trim
Sales $50,000,000-$100,000,000
# of Employees 437
Plant Area (Sq.Ft.) 250,000
Annual Production 660,000 Pieces
Production Hrs. Annual 6,050
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $224,418 6,491,841 kWh $0.03
Electricity Demand $215,696 15,867 kW-months/year $13.59
Natural Gas $269,818 50,521 MMBtu $5.34
TOTAL ENERGY COSTS $917,932
RECOMMENDED SAVINGS* $947,850 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $12,700
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Solid Waste (haz) Primary Raw Material Ancillary Material Cost Electricity Usage Electricity Demand Solid Waste (haz) Primary Raw Material Ancillary Material Cost
$ kWh $ kW-months/year $ lb $ $ $ $
01: 3.2121 CONVERT TO ELECTROSTATIC POWDER COATING Savings:
$934,000
Cost:
$500,000
- - - - $208,000 47,000 $726,000 - - - -
-
kWh
-
-
kW-months/year
$208,000
47,000
lb
$726,000
-
$
-
-
$
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$8,900
Cost:
$400
$5,500 130,000 $3,400 250 - - - - - - $5,500
130,000
kWh
$3,400
250
kW-months/year
-
-
lb
-
-
$
-
-
$
03: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE Savings:
$2,000
Cost:
-
- - - - - - - - $2,000 - -
-
kWh
-
-
kW-months/year
-
-
lb
-
-
$
$2,000
-
$
04: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED Savings:
$1,460
Cost:
$170
$470 11,000 $990 72 - - - - - - $470
11,000
kWh
$990
72
kW-months/year
-
-
lb
-
-
$
-
-
$
05: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE Savings:
$890
Cost:
-
- - - - - - - - $890 - -
-
kWh
-
-
kW-months/year
-
-
lb
-
-
$
$890
-
$
06: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE Savings:
$340
Cost:
-
- - - - - - - - $340 - -
-
kWh
-
-
kW-months/year
-
-
lb
-
-
$
$340
-
$
07: 2.4314 USE SYNTHETIC LUBRICANT Savings:
$260
Cost:
-
$128 3,030 $132 10 - - - - - - $128
3,030
kWh
$132
10
kW-months/year
-
-
lb
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$947,850
Cost:
$500,570
$6,098 144,030 $4,522 332 $208,000 47,000 $726,000 - $3,230 - $6,098
144,030
kWh
$4,522
332
kW-months/year
$208,000
47,000
lb
$726,000
-
$
$3,230
-
$
TOTAL IMPLEMENTED Savings:
$12,700
Cost:
$570
$5,970 141,000 $4,390 322 - - - - $2,340 - $5,970
141,000
kWh
$4,390
322
kW-months/year
-
-
lb
-
-
$
$2,340
-
$
Savings
Cost
$ kWh $ kW-months/year $ lb $ $ $ $
Electricity Usage Electricity Demand Solid Waste (haz) Primary Raw Material Ancillary Material Cost Electricity Usage Electricity Demand Solid Waste (haz) Primary Raw Material Ancillary Material Cost