Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 2007 |
Principal Product | Library furniture |
NAICS | 337127 - Institutional Furniture Manufacturing |
SIC | 2531 - Public Building & Related Furniture |
Sales | $5,000,000-$10,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 93,618 |
Annual Production | 21,600 Pieces |
Production Hrs. Annual | 3,233 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $53,724 | 550,272 | kWh | $0.10 |
Electricity Demand | $30,684 | 3,336 | kW-months/year | $9.20 |
Natural Gas | $22,628 | 2,722 | MMBtu | $8.31 |
TOTAL ENERGY COSTS | $107,036 | |||
RECOMMENDED SAVINGS* | $31,505 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $31,505 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $12,500 Cost: $1,000 |
$10,470 | 103,700 | $2,030 | 385 | - | - | - | - |
$10,470 103,700 kWh |
$2,030 385 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.5115 REPOSITION OVEN WALLS TO REDUCE HEATED SPACE |
Savings: $11,700 Cost: $500 |
$9,800 | 97,000 | $1,900 | 360 | - | - | - | - |
$9,800 97,000 kWh |
$1,900 360 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.8123 PAY UTILITY BILLS ON TIME |
Savings: $4,560 Cost: - |
- | - | - | - | - | - | $4,560 | - |
- - kWh |
- - kW-months/year |
- - $ |
$4,560 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7123 KEEP LAMPS AND REFLECTORS CLEAN |
Savings: $1,810 Cost: - |
$2,540 | 25,150 | - | - | $(-730) | - | - | - |
$2,540 25,150 kWh |
- - kW-months/year |
$(-730) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $390 Cost: $6 |
$330 | 3,270 | $60 | 12 | - | - | - | - |
$330 3,270 kWh |
$60 12 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $340 Cost: - |
$340 | 3,370 | - | - | - | - | - | - |
$340 3,370 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $205 Cost: - |
$170 | 1,710 | $35 | 7 | - | - | - | - |
$170 1,710 kWh |
$35 7 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $31,505 Cost: $1,506 |
$23,650 | 234,200 | $4,025 | 764 | $(-730) | - | $4,560 | - | $23,650 234,200 kWh |
$4,025 764 kW-months/year |
$(-730) - $ |
$4,560 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $31,505 Cost: $1,506 |
$23,650 | 234,200 | $4,025 | 764 | $(-730) | - | $4,560 | - | $23,650 234,200 kWh |
$4,025 764 kW-months/year |
$(-730) - $ |
$4,560 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Personnel Changes | One-time Revenue or Avoided Cost |