IAC logo
IAC Assessment: AM0542
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: AM0542
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Texas A&M, College Station
Assessment Year 2008
Principal Product Structural glazed brick and tile
NAICS 327120 - Clay Building Material and Refractories Manufacturing
SIC 3251 - Brick And Structural Clay Tile
Sales $10,000,000-$50,000,000
# of Employees 90
Plant Area (Sq.Ft.) 400,000
Annual Production 4,800,000 Pounds
Production Hrs. Annual 8,736
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $297,153 3,514,279 kWh $0.08
Electricity Demand $51,145 10,152 kW-months/year $5.04
Electricity Fees $31,429 - $ -
Natural Gas $990,287 154,627 MMBtu $6.40
TOTAL ENERGY COSTS $1,370,014
RECOMMENDED SAVINGS* $45,325 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $26,400
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Electricity Usage Electricity Demand Electricity Fees
$ kWh $ kW-months/year $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$4,800
Cost:
$1,680
$3,800 40,500 $1,000 164 - - $3,800
40,500
kWh
$1,000
164
kW-months/year
-
-
$
02: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES Savings:
$20,100
Cost:
-
- - - - $20,100 - -
-
kWh
-
-
kW-months/year
$20,100
-
$
03: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$12,000
Cost:
$18,000
- - $12,000 2,000 - - -
-
kWh
$12,000
2,000
kW-months/year
-
-
$
04: 4.8210 PAY BILLS ON TIME TO AVOID LATE FEES Savings:
$6,925
Cost:
-
- - - - $6,925 - -
-
kWh
-
-
kW-months/year
$6,925
-
$
05: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$1,500
Cost:
-
$1,500 16,000 - - - - $1,500
16,000
kWh
-
-
kW-months/year
-
-
$
TOTAL RECOMMENDED Savings:
$45,325
Cost:
$19,680
$5,300 56,500 $13,000 2,164 $27,025 - $5,300
56,500
kWh
$13,000
2,164
kW-months/year
$27,025
-
$
TOTAL IMPLEMENTED Savings:
$26,400
Cost:
$1,680
$5,300 56,500 $1,000 164 $20,100 - $5,300
56,500
kWh
$1,000
164
kW-months/year
$20,100
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Electricity Fees Electricity Usage Electricity Demand Electricity Fees