Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 2014 |
Principal Product | Plastic plates, bowls, etc |
NAICS | 326140 - Polystyrene Foam Product Manufacturing |
SIC | 3086 - Plastics Foam Products |
Sales | $100,000,000-$500,000,000 |
# of Employees | 454 |
Plant Area (Sq.Ft.) | 1,700,000 |
Annual Production | 120,000,000 Pounds |
Production Hrs. Annual | 8,520 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $3,346,746 | 96,698,749 | kWh | $0.03 |
Natural Gas | $117,357 | 31,817 | MMBtu | $3.69 |
TOTAL ENERGY COSTS | $3,464,103 | |||
RECOMMENDED SAVINGS* | $866,181 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $682,581 |
#|Description |
Savings Cost |
Status | Electricity Usage | Personnel Changes | Administrative Changes | Primary Product | Electricity Usage | Personnel Changes | Administrative Changes | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $560,000 Cost: - |
- | - | - | - | - | - | $560,000 | - |
- - kWh |
- - $ |
- - $ |
$560,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.445 INSTALL EQUIPMENT TO MOVE PRODUCT |
Savings: $180,000 Cost: $110,000 |
- | - | $130,000 | - | $50,000 | - | - | - |
- - kWh |
$130,000 - $ |
$50,000 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $91,200 Cost: $15,800 |
$91,200 | 1,720,000 | - | - | - | - | - | - |
$91,200 1,720,000 kWh |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $20,161 Cost: $200 |
$20,161 | 380,400 | - | - | - | - | - | - |
$20,161 380,400 kWh |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $5,620 Cost: $3,560 |
$5,620 | 106,020 | - | - | - | - | - | - |
$5,620 106,020 kWh |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $4,470 Cost: $605 |
$4,470 | 84,400 | - | - | - | - | - | - |
$4,470 84,400 kWh |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $3,600 Cost: - |
$3,600 | 67,900 | - | - | - | - | - | - |
$3,600 67,900 kWh |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $1,130 Cost: - |
$1,130 | 21,300 | - | - | - | - | - | - |
$1,130 21,300 kWh |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $866,181 Cost: $130,165 |
$126,181 | 2,380,020 | $130,000 | - | $50,000 | - | $560,000 | - | $126,181 2,380,020 kWh |
$130,000 - $ |
$50,000 - $ |
$560,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $682,581 Cost: $20,165 |
$122,581 | 2,312,120 | - | - | - | - | $560,000 | - | $122,581 2,312,120 kWh |
- - $ |
- - $ |
$560,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Personnel Changes | Administrative Changes | Primary Product | Electricity Usage | Personnel Changes | Administrative Changes | Primary Product |