Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 2023 |
Principal Product | Softwood lumber |
NAICS | 321113 - Sawmills |
SIC | 2421 - Sawmills And Planing Mills, General |
Sales | $50,000,000-$100,000,000 |
# of Employees | 120 |
Plant Area (Sq.Ft.) | 75,000 |
Annual Production | 50,000 Tons |
Production Hrs. Annual | 8,592 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $973,267 | 14,122,008 | kWh | $0.07 |
Electricity Demand | $341,677 | 44,387 | kW-months/year | $7.70 |
Electricity Fees | $53,918 | - | $ | - |
Natural Gas | $143,433 | 26,652 | MMBtu | $5.38 |
TOTAL ENERGY COSTS | $1,512,295 | |||
RECOMMENDED SAVINGS* | $282,455 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $282,455 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Ancillary Material Cost | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $238,195 Cost: $7,000 |
- | - | - | - | $47,639 | - | - | - | $190,556 | - |
- - kWh |
- - kW-months/year |
$47,639 - $ |
- - $ |
$190,556 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $13,145 Cost: $19,096 |
- | - | $13,145 | 1,776 | - | - | - | - | - | - |
- - kWh |
$13,145 1,776 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $10,675 Cost: $1,890 |
$10,675 | 152,476 | - | - | - | - | - | - | - | - |
$10,675 152,476 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4157 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM |
Savings: $6,990 Cost: $11,000 |
$4,040 | 57,700 | - | - | - | - | $2,950 | - | - | - |
$4,040 57,700 kWh |
- - kW-months/year |
- - $ |
$2,950 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $5,720 Cost: $440 |
$3,680 | 52,560 | $2,040 | 144 | - | - | - | - | - | - |
$3,680 52,560 kWh |
$2,040 144 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $5,400 Cost: $770 |
$5,400 | 77,180 | - | - | - | - | - | - | - | - |
$5,400 77,180 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $2,330 Cost: $500 |
$1,440 | 20,630 | $890 | 120 | - | - | - | - | - | - |
$1,440 20,630 kWh |
$890 120 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $282,455 Cost: $40,696 |
$25,235 | 360,546 | $16,075 | 2,040 | $47,639 | - | $2,950 | - | $190,556 | - | $25,235 360,546 kWh |
$16,075 2,040 kW-months/year |
$47,639 - $ |
$2,950 - $ |
$190,556 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $282,455 Cost: $40,696 |
$25,235 | 360,546 | $16,075 | 2,040 | $47,639 | - | $2,950 | - | $190,556 | - | $25,235 360,546 kWh |
$16,075 2,040 kW-months/year |
$47,639 - $ |
$2,950 - $ |
$190,556 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Ancillary Material Cost | One-time Revenue or Avoided Cost |