IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 2023 |
Principal Product | Softwood lumber |
NAICS | 321113 - Sawmills |
SIC | 2421 - Sawmills And Planing Mills, General |
Sales | $50,000,000-$100,000,000 |
# of Employees | 120 |
Plant Area (Sq.Ft.) | 75,000 |
Annual Production | 50,000 Tons |
Production Hrs. Annual | 8,592 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $973,267 | 14,122,008 | kWh | $0.07 |
Electricity Demand | $341,677 | 44,387 | kW-months/year | $7.70 |
Electricity Fees | $53,918 | - | $ | - |
Natural Gas | $143,433 | 26,652 | MMBtu | $5.38 |
TOTAL ENERGY COSTS | $1,512,295 | |||
RECOMMENDED SAVINGS* | $282,455 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Ancillary Material Cost | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $238,195 Cost: $7,000 |
- | - | - | - | $47,639 | - | - | - | $190,556 | - |
- - kWh |
- - kW-months/year |
$47,639 - $ |
- - $ |
$190,556 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $13,145 Cost: $19,096 |
- | - | $13,145 | 1,776 | - | - | - | - | - | - |
- - kWh |
$13,145 1,776 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $10,675 Cost: $1,890 |
$10,675 | 152,476 | - | - | - | - | - | - | - | - |
$10,675 152,476 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4157 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM |
Savings: $6,990 Cost: $11,000 |
$4,040 | 57,700 | - | - | - | - | $2,950 | - | - | - |
$4,040 57,700 kWh |
- - kW-months/year |
- - $ |
$2,950 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $5,720 Cost: $440 |
$3,680 | 52,560 | $2,040 | 144 | - | - | - | - | - | - |
$3,680 52,560 kWh |
$2,040 144 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $5,400 Cost: $770 |
$5,400 | 77,180 | - | - | - | - | - | - | - | - |
$5,400 77,180 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $2,330 Cost: $500 |
$1,440 | 20,630 | $890 | 120 | - | - | - | - | - | - |
$1,440 20,630 kWh |
$890 120 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $282,455 Cost: $40,696 |
$25,235 | 360,546 | $16,075 | 2,040 | $47,639 | - | $2,950 | - | $190,556 | - | $25,235 360,546 kWh |
$16,075 2,040 kW-months/year |
$47,639 - $ |
$2,950 - $ |
$190,556 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Ancillary Material Cost | One-time Revenue or Avoided Cost |