IAC logo
IAC Assessment: AM0949
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: AM0949
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Texas A&M, College Station
Assessment Year 2025
Principal Product severe service ball valves and automation
NAICS 333911 - Pump and Pumping Equipment Manufacturing
SIC 3561 - Pumps And Pumping Equipment
Sales $10,000,000-$50,000,000
# of Employees 160
Plant Area (Sq.Ft.) 75,500
Annual Production 50,000 Units
Production Hrs. Annual 4,165
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $269,747 5,927,198 kWh $0.05
Electricity Demand $182,976 19,653 kW-months/year $9.31
Electricity Fees $40,526 - $ -
Natural Gas $13,128 1,428 MMBtu $9.19
TOTAL ENERGY COSTS $506,376
RECOMMENDED SAVINGS* $292,251 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Electricity Fees One-time Revenue or Avoided Cost
$ kWh $ kW-months/year $ $ $ $
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$93,065
Cost:
$1,113,790
$93,065 1,751,873 - - - - - - $93,065
1,751,873
kWh
-
-
kW-months/year
-
-
$
-
-
$
02: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES Savings:
$147,920
Cost:
$15,000
- - - - $36,980 - $110,940 - -
-
kWh
-
-
kW-months/year
$36,980
-
$
$110,940
-
$
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$22,554
Cost:
$2,925
$22,554 490,300 - - - - - - $22,554
490,300
kWh
-
-
kW-months/year
-
-
$
-
-
$
04: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$14,370
Cost:
$29,250
- - $14,370 1,489 - - - - -
-
kWh
$14,370
1,489
kW-months/year
-
-
$
-
-
$
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$11,153
Cost:
$1,000
$10,473 227,672 $680 73 - - - - $10,473
227,672
kWh
$680
73
kW-months/year
-
-
$
-
-
$
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$2,280
Cost:
$2,129
$234 5,084 $2,046 220 - - - - $234
5,084
kWh
$2,046
220
kW-months/year
-
-
$
-
-
$
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$909
Cost:
$1,080
$537 11,680 $372 40 - - - - $537
11,680
kWh
$372
40
kW-months/year
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$292,251
Cost:
$1,165,174
$126,863 2,486,609 $17,468 1,822 $36,980 - $110,940 - $126,863
2,486,609
kWh
$17,468
1,822
kW-months/year
$36,980
-
$
$110,940
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $
Electricity Usage Electricity Demand Electricity Fees One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Electricity Fees One-time Revenue or Avoided Cost