Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Arizona State University
Assessment Year 2004
Principal Product Aluminum sows
NAICS 331314 - Secondary Smelting and Alloying of Aluminum
SIC 3341 - Secondary Nonferrous Metals
Sales $10,000,000-$50,000,000
# of Employees 60
Plant Area (Sq.Ft.) 1,000,000
Annual Production 139,000,000 Pounds
Production Hrs. Annual 8,760
Location (State) AZ
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $247,039 4,031,304 kWh $0.06
Electricity Demand $12,984 8,323 kW-months/year $1.56
Electricity Fees $19,120 - $ -
Natural Gas $836,445 101,147 MMBtu $8.27
TOTAL ENERGY COSTS $1,115,588
RECOMMENDED SAVINGS* $279,448 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Other Energy Personnel Changes Electricity Usage Electricity Demand Natural Gas Other Energy Personnel Changes
$ kWh $ kW-months/year $ MMBtu $ MMBtu $ $
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$21,304
Cost:
$10,000
- - - - $21,304 6,087 - - - - -
-
kWh
-
-
kW-months/year
$21,304
6,087
MMBtu
-
-
MMBtu
-
-
$
02: 3.1161 ELIMINATE/REDUCE AN OPERATION Savings:
$151,757
Cost:
$37,000
$(-6,572) (-149,370) $(-1,541) (-205) - - $65,700 7,118 $94,170 - $(-6,572)
(-149,370)
kWh
$(-1,541)
(-205)
kW-months/year
-
-
MMBtu
$65,700
7,118
MMBtu
$94,170
-
$
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$59,563
Cost:
$24,322
$48,251 1,096,612 $11,312 1,500 - - - - - - $48,251
1,096,612
kWh
$11,312
1,500
kW-months/year
-
-
MMBtu
-
-
MMBtu
-
-
$
04: 3.5112 REPROCESS SPENT OILS ON SITE FOR RE-USE Savings:
$42,444
Cost:
$17,685
$(-1,734) (-39,420) $(-407) (-54) $44,585 5,650 - - - - $(-1,734)
(-39,420)
kWh
$(-407)
(-54)
kW-months/year
$44,585
5,650
MMBtu
-
-
MMBtu
-
-
$
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$719
Cost:
$506
$719 16,377 - - - - - - - - $719
16,377
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
MMBtu
-
-
$
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$383
Cost:
$30
$310 7,058 $73 10 - - - - - - $310
7,058
kWh
$73
10
kW-months/year
-
-
MMBtu
-
-
MMBtu
-
-
$
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$2,939
Cost:
$60
$2,382 54,147 $557 74 - - - - - - $2,382
54,147
kWh
$557
74
kW-months/year
-
-
MMBtu
-
-
MMBtu
-
-
$
08: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$339
Cost:
$150
- - - - $339 52 - - - - -
-
kWh
-
-
kW-months/year
$339
52
MMBtu
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$279,448
Cost:
$89,753
$43,356 985,404 $9,994 1,325 $66,228 11,789 $65,700 7,118 $94,170 - $43,356
985,404
kWh
$9,994
1,325
kW-months/year
$66,228
11,789
MMBtu
$65,700
7,118
MMBtu
$94,170
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Other Energy Personnel Changes Electricity Usage Electricity Demand Natural Gas Other Energy Personnel Changes