Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Arizona State University
Assessment Year 2022
Principal Product Skilled Nursing Care
NAICS 623110 - Nursing Care Facilities (Skilled Nursing Facilities)
SIC 8051 - Skilled Nursing Care Facilities
Sales $10,000,000-$50,000,000
# of Employees 120
Plant Area (Sq.Ft.) 63,000
Annual Production 1 Units
Production Hrs. Annual 8,736
Location (State) AZ
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $124,904 1,167,449 kWh $0.11
Electricity Demand $20,511 3,279 kW-months/year $6.26
Electricity Fees $2,376 - $ -
LPG $27,000 860 MMBtu $31.41
TOTAL ENERGY COSTS $174,791
RECOMMENDED SAVINGS* $55,704 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $55,645
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$21,984
Cost:
$54,180
$16,851 157,487 $5,133 821 $16,851
157,487
kWh
$5,133
821
kW-months/year
02: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$21,588
Cost:
$279,240
$19,786 184,915 $1,802 288 $19,786
184,915
kWh
$1,802
288
kW-months/year
03: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE Savings:
$11,084
Cost:
$17,430
$11,084 103,589 - - $11,084
103,589
kWh
-
-
kW-months/year
04: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$516
Cost:
$200
$492 4,596 $24 4 $492
4,596
kWh
$24
4
kW-months/year
05: 2.7272 INSTALL HEAT PIPES / RAISE COOLING SETPOINT Savings:
$473
Cost:
$52
$369 3,455 $104 17 $369
3,455
kWh
$104
17
kW-months/year
06: 2.7134 USE PHOTOCELL CONTROLS Savings:
$59
Cost:
$97
$59 548 - - $59
548
kWh
-
-
kW-months/year
TOTAL RECOMMENDED Savings:
$55,704
Cost:
$351,199
$48,641 454,590 $7,063 1,129 $48,641
454,590
kWh
$7,063
1,129
kW-months/year
TOTAL IMPLEMENTED Savings:
$55,645
Cost:
$351,102
$48,582 454,042 $7,063 1,129 $48,582
454,042
kWh
$7,063
1,129
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand