Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Arizona State University
Assessment Year 2023
Principal Product water
NAICS 221310 - Water Supply and Irrigation Systems
SIC 4941 - Water Supply
Sales <$500,000
# of Employees 82
Plant Area (Sq.Ft.) 1,202,942
Annual Production 5,475,000 Thousand Gallons
Production Hrs. Annual 8,760
Location (State) NM
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,035,267 11,370,447 kWh $0.09
Electricity Fees $21,864 - $ -
TOTAL ENERGY COSTS $1,057,131
RECOMMENDED SAVINGS* $144,190 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $1,930
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$102,285
Cost:
$40,427
$102,285 1,124,013 $102,285
1,124,013
kWh
02: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$23,596
Cost:
$10,513
$23,596 259,296 $23,596
259,296
kWh
03: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$5,616
Cost:
$943
$5,616 61,714 $5,616
61,714
kWh
04: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE Savings:
$4,993
Cost:
$5,854
$4,993 54,873 $4,993
54,873
kWh
05: 2.7134 USE PHOTOCELL CONTROLS Savings:
$3,488
Cost:
$7,137
$3,488 38,325 $3,488
38,325
kWh
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$2,282
Cost:
$458
$2,282 25,081 $2,282
25,081
kWh
07: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS Savings:
$1,930
Cost:
$304
$1,930 21,205 $1,930
21,205
kWh
TOTAL RECOMMENDED Savings:
$144,190
Cost:
$65,636
$144,190 1,584,507 $144,190
1,584,507
kWh
TOTAL IMPLEMENTED Savings:
$1,930
Cost:
$304
$1,930 21,205 $1,930
21,205
kWh
Savings
Cost
$ kWh
Electricity Usage Electricity Usage