Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Arizona State University |
---|---|
Assessment Year | 2024 |
Principal Product | Herbicides, Fungicides, and Pesticides |
NAICS | 325320 - Pesticide and Other Agricultural Chemical Manufacturing |
SIC | 2879 - Agricultural Chemicals, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 345 |
Plant Area (Sq.Ft.) | 3,308,382 |
Annual Production | 20,000,000 Units |
Production Hrs. Annual | 8,472 |
Location (State) | AZ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $496,459 | 8,092,080 | kWh | $0.06 |
Electricity Demand | $336,618 | 27,011 | kW-months/year | $12.46 |
Electricity Fees | $6,095 | - | $ | - |
Natural Gas | $119,250 | 10,245 | MMBtu | $11.64 |
LPG | $140,873 | 6,614 | MMBtu | $21.30 |
TOTAL ENERGY COSTS | $1,099,295 | |||
RECOMMENDED SAVINGS* | $155,283 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | LPG | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT |
Savings: $114,491 Cost: $1,279,371 |
$(-44,882) | (-730,981) | - | - | $140,873 | 6,614 | $18,500 | - |
$(-44,882) (-730,981) kWh |
- - kW-months/year |
$140,873 6,614 MMBtu |
$18,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $30,471 Cost: $40,000 |
$23,668 | 385,475 | $6,803 | 556 | - | - | - | - |
$23,668 385,475 kWh |
$6,803 556 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $8,885 Cost: $8,703 |
$6,901 | 112,405 | $1,984 | 159 | - | - | - | - |
$6,901 112,405 kWh |
$1,984 159 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,195 Cost: $514 |
$928 | 15,119 | $267 | 21 | - | - | - | - |
$928 15,119 kWh |
$267 21 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $161 Cost: $322 |
$115 | 1,880 | $46 | 4 | - | - | - | - |
$115 1,880 kWh |
$46 4 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE |
Savings: $80 Cost: $178 |
$50 | 809 | $30 | 2 | - | - | - | - |
$50 809 kWh |
$30 2 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $155,283 Cost: $1,329,088 |
$(-13,220) | (-215,293) | $9,130 | 743 | $140,873 | 6,614 | $18,500 | - | $(-13,220) (-215,293) kWh |
$9,130 743 kW-months/year |
$140,873 6,614 MMBtu |
$18,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | LPG | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | LPG | One-time Revenue or Avoided Cost |