Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Arizona State University |
---|---|
Assessment Year | 2025 |
Principal Product | Investment casting for industrial and aerospace applications |
NAICS | 331512 - Steel Investment Foundries |
SIC | 3324 - Steel Investment Foundries |
Sales | $10,000,000-$50,000,000 |
# of Employees | 120 |
Plant Area (Sq.Ft.) | 108,000 |
Annual Production | 30,000 Units |
Production Hrs. Annual | 6,024 |
Location (State) | AZ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $461,422 | 4,363,680 | kWh | $0.11 |
Electricity Demand | $73,118 | 14,622 | kW-months/year | $5.00 |
Electricity Fees | $33,969 | - | $ | - |
Natural Gas | $84,535 | 7,092 | MMBtu | $11.92 |
Other Energy | $34,860 | 1 | MMBtu | $34,860.00 |
TOTAL ENERGY COSTS | $687,904 | |||
RECOMMENDED SAVINGS* | $793,666 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Ancillary Material Cost | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.721 INITIATE A PROGRAM TO ACQUIRE ISO CERTIFICATION |
Savings: $320,000 Cost: $104,670 |
- | - | - | - | - | - | $320,000 | - |
- - kWh |
- - kW-months/year |
- - $ |
$320,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.3127 USE ADSORPTION, ION EXCHANGE TO REMOVE CONTAMINANTS |
Savings: $279,654 Cost: $313,240 |
- | - | - | - | - | - | $279,654 | - |
- - kWh |
- - kW-months/year |
- - $ |
$279,654 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $172,434 Cost: $1,040,663 |
$176,851 | 1,673,138 | $11,657 | 2,331 | $(-16,074) | - | - | - |
$176,851 1,673,138 kWh |
$11,657 2,331 kW-months/year |
$(-16,074) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.821 PAY BILLS ON TIME TO AVOID LATE FEES |
Savings: $18,772 Cost: $291 |
- | - | - | - | - | - | $18,772 | - |
- - kWh |
- - kW-months/year |
- - $ |
$18,772 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $1,172 Cost: $545 |
$654 | 6,184 | $518 | 104 | - | - | - | - |
$654 6,184 kWh |
$518 104 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $1,156 Cost: $949 |
$1,156 | 10,934 | - | - | - | - | - | - |
$1,156 10,934 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $478 Cost: $246 |
$437 | 4,133 | $41 | 8 | - | - | - | - |
$437 4,133 kWh |
$41 8 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $793,666 Cost: $1,460,604 |
$179,098 | 1,694,389 | $12,216 | 2,443 | $(-16,074) | - | $618,426 | - | $179,098 1,694,389 kWh |
$12,216 2,443 kW-months/year |
$(-16,074) - $ |
$618,426 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Ancillary Material Cost | One-time Revenue or Avoided Cost |