Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of North Carolina, Charlotte
Assessment Year 2022
Principal Product Bread
NAICS 311812 - Commercial Bakeries
SIC 2051 - Bread, Cake, And Related Products
Sales $100,000,000-$500,000,000
# of Employees 200
Plant Area (Sq.Ft.) 210,000
Annual Production 60,000 Tons
Production Hrs. Annual 8,760
Location (State) NC
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $510,843 9,407,520 kWh $0.05
Electricity Demand $145,329 12,129 kW-months/year $11.98
Electricity Fees $560 - $ -
Natural Gas $391,268 46,677 MMBtu $8.38
TOTAL ENERGY COSTS $1,048,000
RECOMMENDED SAVINGS* $132,060 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$38,944
Cost:
-
$26,796 493,480 $12,148 1,014 - - $26,796
493,480
kWh
$12,148
1,014
kW-months/year
-
-
MMBtu
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$18,525
Cost:
$10,000
$13,666 251,675 $4,859 406 - - $13,666
251,675
kWh
$4,859
406
kW-months/year
-
-
MMBtu
03: 2.1212 OPERATE BOILERS ON HIGH FIRE SETTING Savings:
$4,544
Cost:
$10,000
- - - - $4,544 542 -
-
kWh
-
-
kW-months/year
$4,544
542
MMBtu
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$12,343
Cost:
$16,000
$12,343 227,321 - - - - $12,343
227,321
kWh
-
-
kW-months/year
-
-
MMBtu
05: 2.2611 MODERATE COOLING TOWER OUTLET TEMPERATURE Savings:
$3,233
Cost:
-
$3,233 59,541 - - - - $3,233
59,541
kWh
-
-
kW-months/year
-
-
MMBtu
06: 2.1392 REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE Savings:
$7,230
Cost:
$30,000
- - - - $7,230 863 -
-
kWh
-
-
kW-months/year
$7,230
863
MMBtu
07: 2.2425 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER Savings:
$47,241
Cost:
$125,000
- - - - $47,241 5,636 -
-
kWh
-
-
kW-months/year
$47,241
5,636
MMBtu
TOTAL RECOMMENDED Savings:
$132,060
Cost:
$191,000
$56,038 1,032,017 $17,007 1,420 $59,015 7,041 $56,038
1,032,017
kWh
$17,007
1,420
kW-months/year
$59,015
7,041
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas