IAC logo
IAC Assessment: CC0013
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: CC0013
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of North Carolina, Charlotte
Assessment Year 2023
Principal Product Printed Labels
NAICS 323111 - Commercial Printing (except Screen and Books)
SIC 2759 - Commercial Printing, Nec
Sales $10,000,000-$50,000,000
# of Employees 55
Plant Area (Sq.Ft.) 21,500
Annual Production 1,500,000 Thousand Feet
Production Hrs. Annual 7,488
Location (State) SC
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $145,518 2,730,799 kWh $0.05
Electricity Demand $142,210 7,202 kW-months/year $19.75
Electricity Fees $3,893 - $ -
Natural Gas $745 51 MMBtu $14.69
TOTAL ENERGY COSTS $295,642
RECOMMENDED SAVINGS* $63,721 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Water Usage Electricity Usage Electricity Demand Water Usage
$ kWh $ kW-months/year $ Tgal
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$2,074
Cost:
-
$1,373 25,930 $701 36 - - $1,373
25,930
kWh
$701
36
kW-months/year
-
-
Tgal
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$1,363
Cost:
-
$1,363 25,755 - - - - $1,363
25,755
kWh
-
-
kW-months/year
-
-
Tgal
03: 2.3111 HEAT WATER DURING OFF-PEAK PERIODS AND STORE FOR LATER USE Savings:
$4,697
Cost:
$8,400
$629 11,875 $4,068 206 - - $629
11,875
kWh
$4,068
206
kW-months/year
-
-
Tgal
04: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION Savings:
$21,990
Cost:
$40,000
$15,408 291,045 $7,582 384 $(-1,000) (-200,000) $15,408
291,045
kWh
$7,582
384
kW-months/year
$(-1,000)
(-200,000)
Tgal
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$33,597
Cost:
$180,600
$19,380 366,080 $14,217 720 - - $19,380
366,080
kWh
$14,217
720
kW-months/year
-
-
Tgal
TOTAL RECOMMENDED Savings:
$63,721
Cost:
$229,000
$38,153 720,685 $26,568 1,346 $(-1,000) (-200,000) $38,153
720,685
kWh
$26,568
1,346
kW-months/year
$(-1,000)
(-200,000)
Tgal
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
Tgal
Savings
Cost
$ kWh $ kW-months/year $ Tgal
Electricity Usage Electricity Demand Water Usage Electricity Usage Electricity Demand Water Usage