IAC logo
IAC Assessment: CC0022
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: CC0022
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of North Carolina, Charlotte
Assessment Year 2023
Principal Product food distribution
NAICS 541614 - Process, Physical Distribution, and Logistics Consulting Services
SIC 4731 - Freight Transportation Arrangement
Sales $50,000,000-$100,000,000
# of Employees 265
Plant Area (Sq.Ft.) 132,000
Annual Production 100,000,000 Units
Production Hrs. Annual 8,760
Location (State) NC
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $332,788 4,444,614 kWh $0.07
Electricity Demand $36,791 8,160 kW-months/year $4.51
Electricity Fees $7,014 - $ -
Natural Gas $52,303 4,837 MMBtu $10.81
TOTAL ENERGY COSTS $428,896
RECOMMENDED SAVINGS* $120,611 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$30,247
Cost:
$40,000
$27,947 372,626 $2,300 510 - - $27,947
372,626
kWh
$2,300
510
kW-months/year
-
-
MMBtu
02: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE Savings:
$31,058
Cost:
$23,000
- - - - $31,058 2,872 -
-
kWh
-
-
kW-months/year
$31,058
2,872
MMBtu
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$6,613
Cost:
$2,800
$6,110 81,468 $503 112 - - $6,110
81,468
kWh
$503
112
kW-months/year
-
-
MMBtu
04: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$52,693
Cost:
$521,729
$52,693 702,579 - - - - $52,693
702,579
kWh
-
-
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$120,611
Cost:
$587,529
$86,750 1,156,673 $2,803 622 $31,058 2,872 $86,750
1,156,673
kWh
$2,803
622
kW-months/year
$31,058
2,872
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas