IAC logo
IAC Assessment: CC0034
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: CC0034
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of North Carolina, Charlotte
Assessment Year 2024
Principal Product Switchboards and Panelboards
NAICS 335313 - Switchgear and Switchboard Apparatus Manufacturing
SIC 3613 - Switchgear And Switchboard Apparatus
Sales $100,000,000-$500,000,000
# of Employees 650
Plant Area (Sq.Ft.) 230,000
Annual Production 84,000 Units
Production Hrs. Annual 5,928
Location (State) SC
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $319,511 6,390,465 kWh $0.05
Electricity Demand $259,591 18,515 kW-months/year $14.02
Electricity Fees $3,984 - $ -
Natural Gas $283,919 24,372 MMBtu $11.65
TOTAL ENERGY COSTS $867,005
RECOMMENDED SAVINGS* $50,150 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$4,576
Cost:
-
$4,576 91,520 - - - - $4,576
91,520
kWh
-
-
kW-months/year
-
-
MMBtu
02: 2.2425 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER Savings:
$27,911
Cost:
$90,000
- - - - $27,911 2,396 -
-
kWh
-
-
kW-months/year
$27,911
2,396
MMBtu
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$6,767
Cost:
$5,000
$5,084 101,680 $1,683 120 - - $5,084
101,680
kWh
$1,683
120
kW-months/year
-
-
MMBtu
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$5,092
Cost:
$11,542
- - - - $5,092 437 -
-
kWh
-
-
kW-months/year
$5,092
437
MMBtu
05: 2.6215 SHUT OFF AIR CONDITIONING IN WINTER HEATING SEASON Savings:
$3,666
Cost:
-
$3,666 73,324 - - - - $3,666
73,324
kWh
-
-
kW-months/year
-
-
MMBtu
06: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT Savings:
$2,138
Cost:
$2,000
$2,138 42,763 - - - - $2,138
42,763
kWh
-
-
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$50,150
Cost:
$108,542
$15,464 309,287 $1,683 120 $33,003 2,833 $15,464
309,287
kWh
$1,683
120
kW-months/year
$33,003
2,833
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas