IAC logo
IAC Assessment: CC0041
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: CC0041
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of North Carolina, Charlotte
Assessment Year 2024
Principal Product hydraulic piston pumps
NAICS 333996 - Fluid Power Pump and Motor Manufacturing
SIC 3594 - Fluid Power Pumps And Motors
Sales $10,000,000-$50,000,000
# of Employees 150
Plant Area (Sq.Ft.) 90,200
Annual Production 40,000 Units
Production Hrs. Annual 6,240
Location (State) SC
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $293,450 4,853,616 kWh $0.06
Electricity Demand $180,600 9,619 kW-months/year $18.78
Electricity Fees $22,155 - $ -
Natural Gas $15,843 1,331 MMBtu $11.90
TOTAL ENERGY COSTS $512,048
RECOMMENDED SAVINGS* $35,306 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$1,874
Cost:
$6,020
$1,874 30,787 - - $1,874
30,787
kWh
-
-
kW-months/year
02: 2.7229 AIR CONDITION ONLY SPACE NECESSARY Savings:
$8,109
Cost:
-
$5,676 94,608 $2,433 130 $5,676
94,608
kWh
$2,433
130
kW-months/year
03: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$4,448
Cost:
$6,882
$4,448 74,132 - - $4,448
74,132
kWh
-
-
kW-months/year
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$5,256
Cost:
-
$3,679 61,320 $1,577 84 $3,679
61,320
kWh
$1,577
84
kW-months/year
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$180
Cost:
$308
$180 2,993 - - $180
2,993
kWh
-
-
kW-months/year
06: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$12,484
Cost:
-
$12,484 208,073 - - $12,484
208,073
kWh
-
-
kW-months/year
07: 2.7316 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN Savings:
$563
Cost:
-
$394 6,570 $169 9 $394
6,570
kWh
$169
9
kW-months/year
08: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$2,392
Cost:
-
$2,392 39,874 - - $2,392
39,874
kWh
-
-
kW-months/year
TOTAL RECOMMENDED Savings:
$35,306
Cost:
$13,210
$31,127 518,357 $4,179 223 $31,127
518,357
kWh
$4,179
223
kW-months/year
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand