IAC logo
IAC Assessment: CI0028
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: CI0028
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of California, Irvine
Assessment Year 2024
Principal Product Academic Services
NAICS 611110 - Elementary and Secondary Schools
SIC 8211 - Elementary And Secondary Schools
Sales $500,000-$1,000,000
# of Employees 120
Plant Area (Sq.Ft.) 30,000
Annual Production 800 Units
Production Hrs. Annual 1,890
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $155,950 327,690 kWh $0.48
Natural Gas $11,487 492 MMBtu $23.35
Other Gas $828 492 MMBtu $1.68
TOTAL ENERGY COSTS $171,443
RECOMMENDED SAVINGS* $203,730 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Water Usage Electricity Usage Natural Gas Water Usage
$ kWh $ MMBtu $ Tgal
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$117,628
Cost:
$341,230
$117,628 247,170 - - - - $117,628
247,170
kWh
-
-
MMBtu
-
-
Tgal
02: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$43,415
Cost:
$1,900
$43,415 91,226 - - - - $43,415
91,226
kWh
-
-
MMBtu
-
-
Tgal
03: 2.7493 USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES Savings:
$14,256
Cost:
$92,800
$14,256 29,892 - - - - $14,256
29,892
kWh
-
-
MMBtu
-
-
Tgal
04: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$10,253
Cost:
$80,000
$10,253 21,546 - - - - $10,253
21,546
kWh
-
-
MMBtu
-
-
Tgal
05: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$5,668
Cost:
$5,200
$5,668 11,910 - - - - $5,668
11,910
kWh
-
-
MMBtu
-
-
Tgal
06: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT Savings:
$5,530
Cost:
$11,000
$5,530 11,619 - - - - $5,530
11,619
kWh
-
-
MMBtu
-
-
Tgal
07: 3.4151 MINIMIZE WATER USAGE Savings:
$5,321
Cost:
$22,000
- - - - $5,321 1,134 -
-
kWh
-
-
MMBtu
$5,321
1,134
Tgal
08: 2.1224 REPLACE BOILER Savings:
$1,659
Cost:
$8,000
- - $1,659 71 - - -
-
kWh
$1,659
71
MMBtu
-
-
Tgal
TOTAL RECOMMENDED Savings:
$203,730
Cost:
$562,130
$196,750 413,363 $1,659 71 $5,321 1,134 $196,750
413,363
kWh
$1,659
71
MMBtu
$5,321
1,134
Tgal
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
MMBtu
-
-
Tgal
Savings
Cost
$ kWh $ MMBtu $ Tgal
Electricity Usage Natural Gas Water Usage Electricity Usage Natural Gas Water Usage