Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of California, Irvine
Assessment Year 2024
Principal Product Supermarket Display Fixtures
NAICS 337215 - Showcase, Partition, Shelving, and Locker Manufacturing
SIC 2541 - Wood Partitions And Fixtures
Sales $10,000,000-$50,000,000
# of Employees 65
Plant Area (Sq.Ft.) 18,500
Annual Production 18,000,000 Pieces
Production Hrs. Annual 6,120
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $71,835 317,446 kWh $0.23
Electricity Demand $40,077 3,216 kW-months/year $12.46
Electricity Fees $10,759 - $ -
Natural Gas $131 9 MMBtu $14.56
LPG $9,180 428 MMBtu $21.43
Other Gas $206 1 MMBtu $206.00
TOTAL ENERGY COSTS $132,188
RECOMMENDED SAVINGS* $132,418 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand LPG Administrative Changes Ancillary Material Cost Increase in Production Electricity Usage Electricity Demand LPG Administrative Changes Ancillary Material Cost Increase in Production
$ kWh $ kW-months/year $ MMBtu $ $ $ $ $ %
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$57,161
Cost:
$288,868
$52,210 230,710 $4,951 397 - - - - - - - - $52,210
230,710
kWh
$4,951
397
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
%
02: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL Savings:
$34,278
Cost:
$75,000
$34,278 151,470 - - - - - - - - - - $34,278
151,470
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
%
03: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$21,951
Cost:
$31,000
$21,951 97,002 - - - - - - - - - - $21,951
97,002
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
%
04: 2.8227 ADJUST / MAINTAIN FORK LIFT TRUCKS FOR MOST EFFICIENT OPERATION Savings:
$7,997
Cost:
$19,000
$(-763) (-3,370) $(-420) (-34) $9,180 428 - - - - - - $(-763)
(-3,370)
kWh
$(-420)
(-34)
kW-months/year
$9,180
428
MMBtu
-
-
$
-
-
$
-
-
%
05: 2.7134 USE PHOTOCELL CONTROLS Savings:
$5,246
Cost:
$7,920
$3,890 17,191 $885 71 - - $213 - $258 - - - $3,890
17,191
kWh
$885
71
kW-months/year
-
-
MMBtu
$213
-
$
$258
-
$
-
-
%
06: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR Savings:
$2,911
Cost:
$6,699
$(-16,089) (-71,096) - - - - - - - - $19,000 - $(-16,089)
(-71,096)
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
$19,000
-
%
07: 2.7493 USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES Savings:
$2,874
Cost:
$7,990
$2,874 12,698 - - - - - - - - - - $2,874
12,698
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
%
TOTAL RECOMMENDED Savings:
$132,418
Cost:
$436,477
$98,351 434,605 $5,416 435 $9,180 428 $213 - $258 - $19,000 - $98,351
434,605
kWh
$5,416
435
kW-months/year
$9,180
428
MMBtu
$213
-
$
$258
-
$
$19,000
-
%
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
%
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $ $ %
Electricity Usage Electricity Demand LPG Administrative Changes Ancillary Material Cost Increase in Production Electricity Usage Electricity Demand LPG Administrative Changes Ancillary Material Cost Increase in Production