Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 1985
Principal Product TRANSISTORS,DIODES
NAICS n/a
SIC 3674 - Semiconductors And Related Devices
Sales $10,000,000-$50,000,000
# of Employees 250
Plant Area (Sq.Ft.) 0
Annual Production 40,000,000 Pieces
Production Hrs. Annual 4,220
Location (State) CO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $382,507 7,643,611 kWh $0.05
Natural Gas $56,061 11,353 MMBtu $4.94
TOTAL ENERGY COSTS $438,568
RECOMMENDED SAVINGS* $43,174 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $41,590
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7314 REDUCE VENTILATION AIR Savings:
$27,000
Cost:
$399
$4,486 89,683 $22,514 4,559 $4,486
89,683
kWh
$22,514
4,559
MMBtu
02: 2.7314 REDUCE VENTILATION AIR Savings:
$7,279
Cost:
$824
$1,200 24,033 $6,079 1,231 $1,200
24,033
kWh
$6,079
1,231
MMBtu
03: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$2,343
Cost:
$4,000
$2,343 46,893 - - $2,343
46,893
kWh
-
-
MMBtu
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$1,584
Cost:
$3,500
- - $1,584 321 -
-
kWh
$1,584
321
MMBtu
05: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$655
Cost:
$3,000
- - $655 133 -
-
kWh
$655
133
MMBtu
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$173
Cost:
$200
$173 3,517 - - $173
3,517
kWh
-
-
MMBtu
07: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE Savings:
$134
Cost:
$162
- - $134 27 -
-
kWh
$134
27
MMBtu
08: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$4,006
Cost:
$3,619
$4,006 81,184 - - $4,006
81,184
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$43,174
Cost:
$15,704
$12,208 245,310 $30,966 6,271 $12,208
245,310
kWh
$30,966
6,271
MMBtu
TOTAL IMPLEMENTED Savings:
$41,590
Cost:
$12,204
$12,208 245,310 $29,382 5,950 $12,208
245,310
kWh
$29,382
5,950
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas