Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 1989
Principal Product IRON & STEEL CASTINGS
NAICS n/a
SIC 3321 - Gray And Ductile Iron Foundries
Sales $1,000,000-$5,000,000
# of Employees 40
Plant Area (Sq.Ft.) 0
Annual Production 1,500,000 Pounds
Production Hrs. Annual 3,474
Location (State) CO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $104,521 2,010,844 kWh $0.05
Natural Gas $38,066 10,243 MMBtu $3.72
TOTAL ENERGY COSTS $142,587
RECOMMENDED SAVINGS* $3,790 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $2,290
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$720
Cost:
$700
- - $720 193 -
-
kWh
$720
193
MMBtu
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$480
Cost:
$600
- - $480 130 -
-
kWh
$480
130
MMBtu
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$900
Cost:
$500
$900 17,292 - - $900
17,292
kWh
-
-
MMBtu
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$780
Cost:
$200
$780 14,947 - - $780
14,947
kWh
-
-
MMBtu
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$570
Cost:
$400
- - $570 155 -
-
kWh
$570
155
MMBtu
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$340
Cost:
$130
$340 6,448 - - $340
6,448
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$3,790
Cost:
$2,530
$2,020 38,687 $1,770 478 $2,020
38,687
kWh
$1,770
478
MMBtu
TOTAL IMPLEMENTED Savings:
$2,290
Cost:
$1,630
$1,240 23,740 $1,050 285 $1,240
23,740
kWh
$1,050
285
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas