Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 1999 |
Principal Product | bindrs and folders for paper and cassettes |
NAICS | n/a |
SIC | 2782 - Blankbooks And Looseleaf Binders |
Sales | $1,000,000-$5,000,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 23,300 |
Annual Production | 1,200,000 Pieces |
Production Hrs. Annual | 2,236 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $8,997 | 318,875 | kWh | $0.03 |
Electricity Demand | $12,446 | 892 | kW-months/year | $13.95 |
Electricity Fees | $756 | - | $ | - |
Natural Gas | $8,880 | 1,824 | MMBtu | $4.87 |
TOTAL ENERGY COSTS | $33,887 | |||
RECOMMENDED SAVINGS* | $53,850 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $2,390 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | lb | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $5,830 Cost: - |
$1,080 | 59,496 | $4,750 | 343 | - | - | - | - | - | - | - | - | - | - | - | - |
$1,080 59,496 kWh |
$4,750 343 kW-months/year |
- - MMBtu |
- - lb |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,570 Cost: $1,000 |
$440 | 24,033 | $1,910 | 138 | - | - | - | - | - | - | $(-780) | - | - | - | - | - |
$440 24,033 kWh |
$1,910 138 kW-months/year |
- - MMBtu |
- - lb |
- - lb |
$(-780) - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE |
Savings: $820 Cost: $1,000 |
- | - | - | - | $820 | 189 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$820 189 MMBtu |
- - lb |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $680 Cost: - |
$160 | 8,499 | $520 | 38 | - | - | - | - | - | - | - | - | - | - | - | - |
$160 8,499 kWh |
$520 38 kW-months/year |
- - MMBtu |
- - lb |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $450 Cost: $380 |
$100 | 5,569 | $350 | 25 | - | - | - | - | - | - | - | - | - | - | - | - |
$100 5,569 kWh |
$350 25 kW-months/year |
- - MMBtu |
- - lb |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5217 REUSE / RECYCLE/ SELL PAPER PRODUCTS |
Savings: $360 Cost: - |
- | - | - | - | - | - | $360 | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$360 - lb |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $140 Cost: - |
- | - | - | - | - | - | - | - | $160 | 56 | - | - | $(-20) | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$160 56 lb |
- - $ |
$(-20) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.514 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS |
Savings: $44,000 Cost: $1,400 |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | $44,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - lb |
- - $ |
- - $ |
$44,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $53,850 Cost: $3,780 |
$1,780 | 97,597 | $7,530 | 544 | $820 | 189 | $360 | - | $160 | 56 | $(-780) | - | $(-20) | - | $44,000 | - | $1,780 97,597 kWh |
$7,530 544 kW-months/year |
$820 189 MMBtu |
$360 - lb |
$160 56 lb |
$(-780) - $ |
$(-20) - $ |
$44,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $2,390 Cost: $2,000 |
$440 | 24,033 | $1,910 | 138 | $820 | 189 | - | - | - | - | $(-780) | - | - | - | - | - | $440 24,033 kWh |
$1,910 138 kW-months/year |
$820 189 MMBtu |
- - lb |
- - lb |
$(-780) - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | lb | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost | Primary Product |