Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2010 |
Principal Product | Aerospace manufacturing |
NAICS | 336411 - Aircraft Manufacturing |
SIC | 3721 - Aircraft |
Sales | $100,000,000-$500,000,000 |
# of Employees | 243 |
Plant Area (Sq.Ft.) | 170,770 |
Annual Production | 400 Pieces |
Production Hrs. Annual | 3,120 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $216,158 | 5,539,651 | kWh | $0.04 |
Electricity Demand | $220,877 | 11,852 | kW-months/year | $18.64 |
Electricity Fees | $440 | - | $ | - |
Natural Gas | $142,746 | 23,120 | MMBtu | $6.17 |
TOTAL ENERGY COSTS | $580,221 | |||
RECOMMENDED SAVINGS* | $35,940 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $33,440 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,520 Cost: $1,000 |
$2,640 | 57,500 | $1,880 | 92 | - | - | - | - | - | - |
$2,640 57,500 kWh |
$1,880 92 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $14,750 Cost: $1,000 |
- | - | - | - | - | - | - | - | $14,750 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
$14,750 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $8,030 Cost: $35,000 |
$4,990 | 108,900 | $3,040 | 149 | - | - | - | - | - | - |
$4,990 108,900 kWh |
$3,040 149 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $4,750 Cost: $15,000 |
$2,950 | 64,400 | $1,800 | 88 | - | - | - | - | - | - |
$2,950 64,400 kWh |
$1,800 88 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $2,500 Cost: $27,500 |
$660 | 14,500 | $1,260 | 62 | - | - | $580 | - | - | - |
$660 14,500 kWh |
$1,260 62 kW-months/year |
- - $ |
$580 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7314 REDUCE VENTILATION AIR |
Savings: $1,390 Cost: $12,400 |
$670 | 14,700 | $690 | 34 | $20 | - | $10 | - | - | - |
$670 14,700 kWh |
$690 34 kW-months/year |
$20 - $ |
$10 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $35,940 Cost: $91,900 |
$11,910 | 260,000 | $8,670 | 425 | $20 | - | $590 | - | $14,750 | - | $11,910 260,000 kWh |
$8,670 425 kW-months/year |
$20 - $ |
$590 - $ |
$14,750 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $33,440 Cost: $64,400 |
$11,250 | 245,500 | $7,410 | 363 | $20 | - | $10 | - | $14,750 | - | $11,250 245,500 kWh |
$7,410 363 kW-months/year |
$20 - $ |
$10 - $ |
$14,750 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost |