Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 2014
Principal Product Dairy Product
NAICS 311511 - Fluid Milk Manufacturing
SIC 2026 - Fluid Milk
Sales $50,000,000-$100,000,000
# of Employees 105
Plant Area (Sq.Ft.) 20,000
Annual Production 500,000 Pieces
Production Hrs. Annual 8,760
Location (State) CO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $91,839 2,299,280 kWh $0.04
Electricity Demand $100,326 5,115 kW-months/year $19.61
Electricity Fees $1,146 - $ -
Natural Gas $73,432 11,866 MMBtu $6.19
TOTAL ENERGY COSTS $266,743
RECOMMENDED SAVINGS* $16,500 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $16,500
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$5,910
Cost:
$13,360
- - - - $5,910 840 - - -
-
kWh
-
-
kW-months/year
$5,910
840
MMBtu
-
-
$
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$2,740
Cost:
$4,240
$1,670 38,700 $1,070 53 - - - - $1,670
38,700
kWh
$1,070
53
kW-months/year
-
-
MMBtu
-
-
$
03: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$1,750
Cost:
$610
- - - - $1,750 249 - - -
-
kWh
-
-
kW-months/year
$1,750
249
MMBtu
-
-
$
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$1,890
Cost:
$8,590
- - - - $1,890 268 - - -
-
kWh
-
-
kW-months/year
$1,890
268
MMBtu
-
-
$
05: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES Savings:
$4,210
Cost:
$1,500
- - - - - - $4,210 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$4,210
-
$
TOTAL RECOMMENDED Savings:
$16,500
Cost:
$28,300
$1,670 38,700 $1,070 53 $9,550 1,357 $4,210 - $1,670
38,700
kWh
$1,070
53
kW-months/year
$9,550
1,357
MMBtu
$4,210
-
$
TOTAL IMPLEMENTED Savings:
$16,500
Cost:
$28,300
$1,670 38,700 $1,070 53 $9,550 1,357 $4,210 - $1,670
38,700
kWh
$1,070
53
kW-months/year
$9,550
1,357
MMBtu
$4,210
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $