IAC logo
IAC Assessment: DL0013
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: DL0013
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Delaware
Assessment Year 2008
Principal Product Monomers, Polyester Acrylates,Sarbox
NAICS 325199 - All Other Basic Organic Chemical Manufacturing
SIC 2821 - Plastics Materials And Resins
Sales $100,000,000-$500,000,000
# of Employees 95
Plant Area (Sq.Ft.) 25,000
Annual Production 1,000 Units
Production Hrs. Annual 6,000
Location (State) PA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $502,960 9,370,590 kWh $0.05
Electricity Demand $214,977 1,286 kW-months/year $167.17
Natural Gas $1,241,710 127,804 MMBtu $9.72
Fuel Oil #2 $578,359 38,502 MMBtu $15.02
TOTAL ENERGY COSTS $2,656,684
RECOMMENDED SAVINGS* $158,914 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $158,914
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$18,300
Cost:
-
$3,000 37,500 $15,300 1,600 $3,000
37,500
kWh
$15,300
1,600
MMBtu
02: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$2,396
Cost:
$285
$2,396 29,952 - - $2,396
29,952
kWh
-
-
MMBtu
03: 2.2511 INSULATE BARE EQUIPMENT Savings:
$108,300
Cost:
$104,800
- - $108,300 11,300 -
-
kWh
$108,300
11,300
MMBtu
04: 2.1243 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER Savings:
$24,218
Cost:
$25,000
- - $24,218 2,528 -
-
kWh
$24,218
2,528
MMBtu
05: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING Savings:
$5,700
Cost:
$10,000
$5,700 43,575 - - $5,700
43,575
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$158,914
Cost:
$140,085
$11,096 111,027 $147,818 15,428 $11,096
111,027
kWh
$147,818
15,428
MMBtu
TOTAL IMPLEMENTED Savings:
$158,914
Cost:
$140,085
$11,096 111,027 $147,818 15,428 $11,096
111,027
kWh
$147,818
15,428
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas