Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Delaware
Assessment Year 2008
Principal Product Fabricated Architectural Glass
NAICS 339999 - All Other Miscellaneous Manufacturing
SIC 5039 - Construction Materials, Nec
Sales $10,000,000-$50,000,000
# of Employees 250
Plant Area (Sq.Ft.) 183,000
Annual Production 16,000 Thousand Feet
Production Hrs. Annual 7,488
Location (State) NJ
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $731,400 731,400 kWh $1.00
Electricity Demand $43,400 43,400 kW-months/year $1.00
Natural Gas $167 12,330 MMBtu $0.01
TOTAL ENERGY COSTS $784,139
RECOMMENDED SAVINGS* $103,668 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $15,917
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$19,500
Cost:
$1,000
$19,500 150,000 - - $19,500
150,000
kWh
-
-
kW-months/year
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$12,550
Cost:
-
$10,800 83,000 $1,750 180 $10,800
83,000
kWh
$1,750
180
kW-months/year
03: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$11,172
Cost:
$700
$11,172 85,938 - - $11,172
85,938
kWh
-
-
kW-months/year
04: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$3,343
Cost:
$590
$3,343 25,718 - - $3,343
25,718
kWh
-
-
kW-months/year
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$2,304
Cost:
$500
$2,304 17,725 - - $2,304
17,725
kWh
-
-
kW-months/year
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$635
Cost:
$160
$635 4,887 - - $635
4,887
kWh
-
-
kW-months/year
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$24
Cost:
$2,394
$24 10,290 - - $24
10,290
kWh
-
-
kW-months/year
08: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$38,540
Cost:
$125,000
$38,540 2,840 - - $38,540
2,840
kWh
-
-
kW-months/year
09: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$15,600
Cost:
$600,000
$15,600 120,000 - - $15,600
120,000
kWh
-
-
kW-months/year
TOTAL RECOMMENDED Savings:
$103,668
Cost:
$730,344
$101,918 500,398 $1,750 180 $101,918
500,398
kWh
$1,750
180
kW-months/year
TOTAL IMPLEMENTED Savings:
$15,917
Cost:
$2,984
$14,167 119,008 $1,750 180 $14,167
119,008
kWh
$1,750
180
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand