Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Delaware
Assessment Year 2012
Principal Product Coffee
NAICS 311920 - Coffee and Tea Manufacturing
SIC 2095 - Roasted Coffee
Sales $5,000,000-$10,000,000
# of Employees 35
Plant Area (Sq.Ft.) 97,000
Annual Production 10,000,000 Pounds
Production Hrs. Annual 6,000
Location (State) NJ
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $228,207 1,944,083 kWh $0.12
Natural Gas $111,846 12,837 MMBtu $8.71
TOTAL ENERGY COSTS $340,053
RECOMMENDED SAVINGS* $87,203 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$2,165
Cost:
$100
$2,165 18,500 - - $2,165
18,500
kWh
-
-
MMBtu
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$13,000
Cost:
$3,500
$13,000 111,000 - - $13,000
111,000
kWh
-
-
MMBtu
03: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$3,160
Cost:
$1,000
$3,160 27,000 - - $3,160
27,000
kWh
-
-
MMBtu
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$44,062
Cost:
$50,400
$44,062 376,600 - - $44,062
376,600
kWh
-
-
MMBtu
05: 2.2531 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR Savings:
$12,281
Cost:
$225
- - $12,281 1,410 -
-
kWh
$12,281
1,410
MMBtu
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$7,582
Cost:
$15,000
$7,582 64,800 - - $7,582
64,800
kWh
-
-
MMBtu
07: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$2,793
Cost:
$100
$2,793 23,870 - - $2,793
23,870
kWh
-
-
MMBtu
08: 2.1133 ADJUST BURNERS FOR EFFICIENT OPERATION Savings:
$2,160
Cost:
$2,160
- - $2,160 248 -
-
kWh
$2,160
248
MMBtu
TOTAL RECOMMENDED Savings:
$87,203
Cost:
$72,485
$72,762 621,770 $14,441 1,658 $72,762
621,770
kWh
$14,441
1,658
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas