Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Delaware
Assessment Year 2012
Principal Product Aluminium Enclosures
NAICS 332999 - All Other Miscellaneous Fabricated Metal Product Manufacturing
SIC 3499 - Fabricated Metal Products, Nec
Sales $5,000,000-$10,000,000
# of Employees 82
Plant Area (Sq.Ft.) 52,000
Annual Production 500,000 Pieces
Production Hrs. Annual 2,142
Location (State) MD
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $100,225 1,043,647 kWh $0.10
Natural Gas $20,507 1,522 MMBtu $13.47
TOTAL ENERGY COSTS $120,732
RECOMMENDED SAVINGS* $16,906 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $8,114
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE Savings:
$7,140
Cost:
$100
$7,140 73,600 - - $7,140
73,600
kWh
-
-
MMBtu
02: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$2,870
Cost:
$818
- - $2,870 213 -
-
kWh
$2,870
213
MMBtu
03: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$1,360
Cost:
$50
$1,360 14,000 - - $1,360
14,000
kWh
-
-
MMBtu
04: 2.7312 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE Savings:
$1,680
Cost:
$5,000
$1,680 17,500 - - $1,680
17,500
kWh
-
-
MMBtu
05: 2.7314 REDUCE VENTILATION AIR Savings:
$1,102
Cost:
$600
$119 1,218 $983 73 $119
1,218
kWh
$983
73
MMBtu
06: 2.7313 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING Savings:
$940
Cost:
$230
$100 1,050 $840 62 $100
1,050
kWh
$840
62
MMBtu
07: 2.7316 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN Savings:
$360
Cost:
$20
- - $360 25 -
-
kWh
$360
25
MMBtu
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$974
Cost:
$480
$974 10,043 - - $974
10,043
kWh
-
-
MMBtu
09: 2.2523 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS Savings:
$480
Cost:
$425
$480 4,960 - - $480
4,960
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$16,906
Cost:
$7,723
$11,853 122,371 $5,053 373 $11,853
122,371
kWh
$5,053
373
MMBtu
TOTAL IMPLEMENTED Savings:
$8,114
Cost:
$580
$8,114 83,643 - - $8,114
83,643
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas