IAC logo
IAC Assessment: DL0227
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: DL0227
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Delaware
Assessment Year 2023
Principal Product Beer and alcoholic beverages distributor
NAICS 424810 - Beer and Ale Merchant Wholesalers
SIC 5181 - Beer And Ale
Sales <$500,000
# of Employees 150
Plant Area (Sq.Ft.) 190,000
Annual Production 1 Units
Production Hrs. Annual 4,940
Location (State) VA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $108,643 1,129,382 kWh $0.10
Electricity Demand $12,096 3,216 kW-months/year $3.76
Electricity Fees $532 - $ -
Natural Gas $44,628 3,797 MMBtu $11.75
TOTAL ENERGY COSTS $165,899
RECOMMENDED SAVINGS* $35,816 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $31,149
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$10,298
Cost:
-
$10,298 96,241 - - $10,298
96,241
kWh
-
-
MMBtu
02: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$8,653
Cost:
-
$8,653 80,871 - - $8,653
80,871
kWh
-
-
MMBtu
03: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$1,027
Cost:
$552
$1,027 9,599 - - $1,027
9,599
kWh
-
-
MMBtu
04: 2.2211 USE OPTIMUM TEMPERATURE Savings:
$6,362
Cost:
-
- - $6,362 541 -
-
kWh
$6,362
541
MMBtu
05: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$3,640
Cost:
$10,608
$6,509 60,830 $(-2,869) (-244) $6,509
60,830
kWh
$(-2,869)
(-244)
MMBtu
06: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$5,836
Cost:
$30,292
$5,836 54,543 - - $5,836
54,543
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$35,816
Cost:
$41,452
$32,323 302,084 $3,493 297 $32,323
302,084
kWh
$3,493
297
MMBtu
TOTAL IMPLEMENTED Savings:
$31,149
Cost:
$30,292
$24,787 231,655 $6,362 541 $24,787
231,655
kWh
$6,362
541
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas