IAC logo
IAC Assessment: DL0229
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: DL0229
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Delaware
Assessment Year 2023
Principal Product life sciences instrumentation
NAICS 334516 - Analytical Laboratory Instrument Manufacturing
SIC 3826 - Analytical Instruments
Sales $50,000,000-$100,000,000
# of Employees 490
Plant Area (Sq.Ft.) 354,000
Annual Production 200 Units
Production Hrs. Annual 3,640
Location (State) DE
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $266,934 3,114,056 kWh $0.09
Electricity Demand $70,870 15,085 kW-months/year $4.70
Electricity Fees $8,294 - $ -
Natural Gas $429,996 72,317 MMBtu $5.95
TOTAL ENERGY COSTS $776,094
RECOMMENDED SAVINGS* $254,792 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$61,397
Cost:
-
$61,397 568,493 - - $61,397
568,493
kWh
-
-
MMBtu
02: 2.7314 REDUCE VENTILATION AIR Savings:
$32,353
Cost:
-
$18,693 173,080 $13,660 1,054 $18,693
173,080
kWh
$13,660
1,054
MMBtu
03: 2.2211 USE OPTIMUM TEMPERATURE Savings:
$8,303
Cost:
-
$17,012 157,517 $(-8,709) (-672) $17,012
157,517
kWh
$(-8,709)
(-672)
MMBtu
04: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS Savings:
$44,923
Cost:
$1,275
$44,923 415,956 - - $44,923
415,956
kWh
-
-
MMBtu
05: 2.7234 USE HEAT PUMP FOR SPACE CONDITIONING Savings:
$2,948
Cost:
$14,000
$1,341 12,420 $1,607 124 $1,341
12,420
kWh
$1,607
124
MMBtu
06: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$104,868
Cost:
$500,000
$77,496 717,554 $27,372 2,112 $77,496
717,554
kWh
$27,372
2,112
MMBtu
TOTAL RECOMMENDED Savings:
$254,792
Cost:
$515,275
$220,862 2,045,020 $33,930 2,618 $220,862
2,045,020
kWh
$33,930
2,618
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas