IAC logo
IAC Assessment: DL0249
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: DL0249
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Delaware
Assessment Year 2025
Principal Product Asphalt
NAICS 324121 - Asphalt Paving Mixture and Block Manufacturing
SIC 2951 - Asphalt Paving Mixtures And Blocks
Sales $10,000,000-$50,000,000
# of Employees 50
Plant Area (Sq.Ft.) 50,000
Annual Production 300,000 Tons
Production Hrs. Annual 1,850
Location (State) NJ
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $144,993 530,919 kWh $0.27
Electricity Demand $59,962 3,080 kW-months/year $19.47
Electricity Fees $240 - $ -
Natural Gas $163,436 32,687 MMBtu $5.00
TOTAL ENERGY COSTS $368,631
RECOMMENDED SAVINGS* $120,053 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$43,100
Cost:
$30,000
$30,481 111,652 $12,619 651 - - $30,481
111,652
kWh
$12,619
651
kW-months/year
-
-
MMBtu
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$17,975
Cost:
$20,000
$12,712 46,563 $5,263 271 - - $12,712
46,563
kWh
$5,263
271
kW-months/year
-
-
MMBtu
03: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$2,075
Cost:
$1,777
- - - - $2,075 415 -
-
kWh
-
-
kW-months/year
$2,075
415
MMBtu
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$3,102
Cost:
$10,000
$2,193 8,043 $909 47 - - $2,193
8,043
kWh
$909
47
kW-months/year
-
-
MMBtu
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$6,172
Cost:
$13,000
- - - - $6,172 1,234 -
-
kWh
-
-
kW-months/year
$6,172
1,234
MMBtu
06: 2.2511 INSULATE BARE EQUIPMENT Savings:
$35,225
Cost:
$8,950
- - - - $35,225 7,045 -
-
kWh
-
-
kW-months/year
$35,225
7,045
MMBtu
07: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$7,174
Cost:
$15,000
$5,074 18,586 $2,100 108 - - $5,074
18,586
kWh
$2,100
108
kW-months/year
-
-
MMBtu
08: 2.1221 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES Savings:
$5,230
Cost:
$38,000
- - - - $5,230 1,046 -
-
kWh
-
-
kW-months/year
$5,230
1,046
MMBtu
TOTAL RECOMMENDED Savings:
$120,053
Cost:
$136,727
$50,460 184,844 $20,891 1,077 $48,702 9,740 $50,460
184,844
kWh
$20,891
1,077
kW-months/year
$48,702
9,740
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas