Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Delaware |
---|---|
Assessment Year | 2025 |
Principal Product | Asphalt |
NAICS | 324121 - Asphalt Paving Mixture and Block Manufacturing |
SIC | 2951 - Asphalt Paving Mixtures And Blocks |
Sales | $5,000,000-$10,000,000 |
# of Employees | 20 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 265,000 Tons |
Production Hrs. Annual | 2,200 |
Location (State) | DE |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $50,777 | 734,079 | kWh | $0.07 |
Electricity Demand | $28,460 | 4,131 | kW-months/year | $6.89 |
Electricity Fees | $9,608 | - | $ | - |
Natural Gas | $370,505 | 70,034 | MMBtu | $5.29 |
Other Gas | $14,905 | 1 | MMBtu | $14,905.00 |
TOTAL ENERGY COSTS | $474,255 | |||
RECOMMENDED SAVINGS* | $133,177 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $17,794 Cost: $10,000 |
$11,366 | 164,724 | $6,428 | 933 | - | - |
$11,366 164,724 kWh |
$6,428 933 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $943 Cost: - |
$943 | 13,664 | - | - | - | - |
$943 13,664 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7234 USE HEAT PUMP FOR SPACE CONDITIONING |
Savings: $1,746 Cost: $7,000 |
$1,115 | 16,163 | $631 | 92 | - | - |
$1,115 16,163 kWh |
$631 92 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $3,650 Cost: $4,699 |
- | - | - | - | $3,650 | 690 |
- - kWh |
- - kW-months/year |
$3,650 690 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4145 INSTALL ISOLATION TRANSFORMER ON ADJUSTABLE FREQUENCY DRIVE |
Savings: $6,715 Cost: $20,000 |
$4,289 | 62,120 | $2,426 | 352 | - | - |
$4,289 62,120 kWh |
$2,426 352 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4222 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN |
Savings: $1,559 Cost: $7,500 |
$996 | 14,438 | $563 | 82 | - | - |
$996 14,438 kWh |
$563 82 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1221 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES |
Savings: $11,855 Cost: $58,000 |
- | - | - | - | $11,855 | 2,241 |
- - kWh |
- - kW-months/year |
$11,855 2,241 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.114 ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS |
Savings: $88,915 Cost: $400,000 |
- | - | - | - | $88,915 | 16,808 |
- - kWh |
- - kW-months/year |
$88,915 16,808 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $133,177 Cost: $507,199 |
$18,709 | 271,109 | $10,048 | 1,458 | $104,420 | 19,739 | $18,709 271,109 kWh |
$10,048 1,458 kW-months/year |
$104,420 19,739 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |