Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 2000 |
Principal Product | Cotton Mats / Wool Rugs |
NAICS | n/a |
SIC | 2273 - Carpets And Rugs |
Sales | $5,000,000-$10,000,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 50,000 |
Annual Production | 1,800,000 Pieces |
Production Hrs. Annual | 2,000 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $32,917 | 483,880 | kWh | $0.07 |
Electricity Demand | $7,819 | 2,553 | kW-months/year | $3.06 |
Electricity Fees | $6,514 | - | $ | - |
Natural Gas | $50,969 | 6,848 | MMBtu | $7.44 |
TOTAL ENERGY COSTS | $111,973 | |||
RECOMMENDED SAVINGS* | $46,790 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $2,267 Cost: - |
- | - | - | - | - | - | - | - | - | - | $2,267 | - | - | - |
- - kW-months/year |
- - $ |
- - MMBtu |
- - lb |
- - $ |
$2,267 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.114 ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS |
Savings: $3,232 Cost: $900 |
- | - | - | - | $742 | 83 | - | - | $2,490 | - | - | - | - | - |
- - kW-months/year |
- - $ |
$742 83 MMBtu |
- - lb |
$2,490 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $700 Cost: $450 |
- | - | - | - | $700 | 78 | - | - | - | - | - | - | - | - |
- - kW-months/year |
- - $ |
$700 78 MMBtu |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $888 Cost: - |
$838 | 19 | $50 | - | - | - | - | - | - | - | - | - | - | - |
$838 19 kW-months/year |
$50 - $ |
- - MMBtu |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1223 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) |
Savings: $14,296 Cost: $28,000 |
- | - | - | - | $14,296 | 1,505 | - | - | - | - | - | - | - | - |
- - kW-months/year |
- - $ |
$14,296 1,505 MMBtu |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $6,035 Cost: $10,000 |
- | - | - | - | - | - | $6,035 | 8,700 | - | - | - | - | - | - |
- - kW-months/year |
- - $ |
- - MMBtu |
$6,035 8,700 lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.2123 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS |
Savings: $1,980 Cost: $1,000 |
- | - | - | - | - | - | - | - | - | - | - | - | $1,980 | - |
- - kW-months/year |
- - $ |
- - MMBtu |
- - lb |
- - $ |
- - $ |
$1,980 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.8112 COMBINE UTILITY METERS |
Savings: $15,392 Cost: - |
- | - | - | - | - | - | - | - | - | - | $15,392 | - | - | - |
- - kW-months/year |
- - $ |
- - MMBtu |
- - lb |
- - $ |
$15,392 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $2,000 Cost: $5,400 |
- | - | - | - | $2,000 | 224 | - | - | - | - | - | - | - | - |
- - kW-months/year |
- - $ |
$2,000 224 MMBtu |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $46,790 Cost: $45,750 |
$838 | 19 | $50 | - | $17,738 | 1,890 | $6,035 | 8,700 | $2,490 | - | $17,659 | - | $1,980 | - | $838 19 kW-months/year |
$50 - $ |
$17,738 1,890 MMBtu |
$6,035 8,700 lb |
$2,490 - $ |
$17,659 - $ |
$1,980 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - - kW-months/year |
- - $ |
- - MMBtu |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost |