Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 2006 |
Principal Product | Nylon & Polypropylene yarn |
NAICS | 325220 - Artificial and Synthetic Fibers and Filaments Manufacturing |
SIC | 2824 - Organic Fibers, Noncellulosic |
Sales | $100,000,000-$500,000,000 |
# of Employees | 367 |
Plant Area (Sq.Ft.) | 398,184 |
Annual Production | 64,000 Tons |
Production Hrs. Annual | 8,760 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $2,975,396 | 90,163,524 | kWh | $0.03 |
Electricity Demand | $229,177 | 149,760 | kW-months/year | $1.53 |
Natural Gas | $17,312 | 1,364 | MMBtu | $12.69 |
TOTAL ENERGY COSTS | $3,221,885 | |||
RECOMMENDED SAVINGS* | $645,301 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $570,623 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Water Consumption | Primary Product | Electricity Usage | Electricity Demand | Water Disposal | Water Consumption | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.4156 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE |
Savings: $22,995 Cost: $640 |
- | - | - | - | $16,203 | 9,702,576 | $6,792 | - | - | - |
- - kWh |
- - kW-months/year |
$16,203 9,702,576 Tgal |
$6,792 - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $3,292 Cost: $10,800 |
$3,292 | 99,757 | - | - | - | - | - | - | - | - |
$3,292 99,757 kWh |
- - kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $97,628 Cost: $18,865 |
$97,628 | 2,958,411 | - | - | - | - | - | - | - | - |
$97,628 2,958,411 kWh |
- - kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $6,620 Cost: $850 |
$6,620 | 200,626 | - | - | - | - | - | - | - | - |
$6,620 200,626 kWh |
- - kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $60,069 Cost: $87,937 |
$53,342 | 1,616,464 | $6,727 | 2,220 | - | - | - | - | - | - |
$53,342 1,616,464 kWh |
$6,727 2,220 kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.8112 COMBINE UTILITY METERS |
Savings: $4,697 Cost: - |
- | - | $4,697 | - | - | - | - | - | - | - |
- - kWh |
$4,697 - kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3511 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS |
Savings: $450,000 Cost: $20,000 |
- | - | - | - | - | - | - | - | $450,000 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - Tgal |
$450,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $645,301 Cost: $139,092 |
$160,882 | 4,875,258 | $11,424 | 2,220 | $16,203 | 9,702,576 | $6,792 | - | $450,000 | - | $160,882 4,875,258 kWh |
$11,424 2,220 kW-months/year |
$16,203 9,702,576 Tgal |
$6,792 - Tgal |
$450,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $570,623 Cost: $39,505 |
$97,628 | 2,958,411 | - | - | $16,203 | 9,702,576 | $6,792 | - | $450,000 | - | $97,628 2,958,411 kWh |
- - kW-months/year |
$16,203 9,702,576 Tgal |
$6,792 - Tgal |
$450,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Water Consumption | Primary Product | Electricity Usage | Electricity Demand | Water Disposal | Water Consumption | Primary Product |